Evidence map›Paper›PMID 32252160›Full record

ArticleNeurospine2020

Telerobotic Spinal Surgery Based on 5G Network: The First 12 Cases.

Wei Tian, Mingxing Fan, Cheng Zeng, Yajun Liu, Da He, Qi Zhang

Registry-linked trialOpen access · diamondAbstract read
In one paragraph

Article in Neurospine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05739812 (The Efficacy and Safety of Chinese Domestic Surgical Robot System in Urological Telesurgery, an Exploratory Study), which is not on this map. Cited by 73 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
73citing papers in PubMed, 4 pooled it
34.5field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05739812 naunknown statusnot on this mapstarted 2023, after this paper: background citation

The Efficacy and Safety of Chinese Domestic Surgical Robot System in Urological Telesurgery, an Exploratory Study

TypeinterventionalSponsorThe Affiliated Hospital of Qingdao UniversityRan2023 to 2024Enrolled100ConditionsRenal Cell Carcinoma, Adrenal Tumor, Nonfunctioning Kidney, Renal Pelvis CarcinomaArmstelesurgery by domestic surgical robot
3 · Its place in the literature

Who cites it

73 citing papers in PubMed, 4 syntheses or guidelines pooled it, 244 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Robotic surgery in emergency setting: 2021 WSES position paper.World journal of emergency surgery : WJES · 2022
    Pooled it
  4. Pooled it
  5. Trial
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Global analysis and prospects of assisted pedicle screw placement surgery: a bibliometric study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  13. Article
  14. Letter to the editor concerning " 5G-Enabled remote Robotic-Assisted percutaneous pedicle screw fixation in single thoracolumbar fractures: initial clinical feasibility and safety evaluation " by L. Zhou, et al. (Eur spine J [2025]: doi: 10.1007/s00586-025-09478-5).European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  15. 5G-Enabled remote Robotic-Assisted percutaneous pedicle screw fixation in single thoracolumbar fractures: initial clinical feasibility and safety evaluation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  16. Review
  17. Review
  18. Article
  19. Article
  20. Review

13 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Wei TianSpine Department, Beijing Jishuitan Hospital, Beijing, China.
Mingxing FanSpine Department, Beijing Jishuitan Hospital, Beijing, China.
Cheng ZengSpine Department, Beijing Jishuitan Hospital, Beijing, China.
Yajun LiuSpine Department, Beijing Jishuitan Hospital, Beijing, China.
Da HeSpine Department, Beijing Jishuitan Hospital, Beijing, China.
Qi ZhangSpine Department, Beijing Jishuitan Hospital, Beijing, China.
Peking University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe purpose of this study was to determine the efficacy and feasibility of 5th generation wireless systems (5G) telerobotic spinal surgery in our first 12 cases.

methodsA total of 12 patients (5 males, 7 females; age, 23-71 years) with spinal disorders (4 thoracolumbar fractures, 6 lumbar spondylolisthesis, 2 lumbar stenosis) were treated with 5G telerobotic spinal surgery. Sixty-two pedicle screws were implanted.

resultsAll patients had substantial relief from their symptoms. Screw placements were classified using Gertzbein-Robbins criteria. There were 59 grade A, 3 grade B. Mean operation time was 142.5 ± 46.7 minutes. Mean guiding wire insertion time was 41.3 ± 9.8 minutes. The deviation between the planned and actual positions was 0.76 ± 0.49 mm. No intraoperative adverse event was found.

conclusion5G remote robot-assisted spinal surgery is accurate and reliable. We conclude that 5G telerobotic spinal surgery is both efficacious and feasible for the management of spinal diseases with safety.

Indexed as

5GOrthopaedicsRemote surgeryRobotic surgeryTelemedicineTelesurgery

Identifiers

PMID32252160
PMCPMC7136105
OpenAlexW3014562972

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.