ArticleNeurospine2020
Telerobotic Spinal Surgery Based on 5G Network: The First 12 Cases.
Article in Neurospine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05739812 (The Efficacy and Safety of Chinese Domestic Surgical Robot System in Urological Telesurgery, an Exploratory Study), which is not on this map. Cited by 73 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Efficacy and Safety of Chinese Domestic Surgical Robot System in Urological Telesurgery, an Exploratory Study
Who cites it
73 citing papers in PubMed, 4 syntheses or guidelines pooled it, 244 citations in OpenAlex.
- A Smarter Health through the Internet of Surgical Things.Sensors (Basel, Switzerland) · 2022Pooled it
- Remote telesurgery in humans: a systematic review.Surgical endoscopy · 2022Pooled it
- Robotic surgery in emergency setting: 2021 WSES position paper.World journal of emergency surgery : WJES · 2022Pooled it
- Telehealth in Urology: A Systematic Review of the Literature. How Much Can Telemedicine Be Useful During and After the COVID-19 Pandemic?European urology · 2020Pooled it
- Reliability of urological telesurgery compared with local surgery: multicentre randomised controlled trial.BMJ (Clinical research ed.) · 2026Trial
- 5G-remote radical prostatectomy under novel robotic systems: a prospective comparative cohort study with local surgeries.Prostate cancer and prostatic diseases · 2026Article
- A retrospective cohort study comparing combined TiRobot navigation and percutaneous minimally invasive FNS fixation versus conventional open reduction FNS for femoral neck fractures.Journal of robotic surgery · 2026Article
- Feasibility and Safety of Cross-Regional 5G-Enabled Remote Robot-Assisted Laparoscopic Surgery: A Retrospective Case Series of 21 Patients.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026Article
- Clinical Recommendations for Remote Robotic Assisted Surgery From the CRSA 2025 International Consensus Conference.World journal of surgery · 2026Article
- Next-Generation Surgery: Integrating Artificial Intelligence, Genetic Technologies, Bioengineering and Rehabilitation Into Modern Practices.Exploration (Beijing, China) · 2026Article
- Telemedicine and 5G Technologies: A Systematic Global Review of Applications over the Past Decade.Bioengineering (Basel, Switzerland) · 2026Review
- Global analysis and prospects of assisted pedicle screw placement surgery: a bibliometric study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- A readiness framework for tele-robotic surgery deployment in rural hospitals.Journal of robotic surgery · 2026Article
- Letter to the editor concerning " 5G-Enabled remote Robotic-Assisted percutaneous pedicle screw fixation in single thoracolumbar fractures: initial clinical feasibility and safety evaluation " by L. Zhou, et al. (Eur spine J [2025]: doi: 10.1007/s00586-025-09478-5).European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- 5G-Enabled remote Robotic-Assisted percutaneous pedicle screw fixation in single thoracolumbar fractures: initial clinical feasibility and safety evaluation.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- A decade of progress in orthopaedic telesurgery from concept to clinical feasibility: an evidence based review of robotics, latency science, digital ecosystems, and future remote surgical practice.Journal of robotic surgery · 2026Review
- Telerobotic surgery: a comprehensive two-decade evolution and the integration of emerging technologies.International journal of surgery (London, England) · 2026Review
- Role and impact of telemedicine in spine surgery: a systematic review.EFORT open reviews · 2025Article
- [Pioneering Application of a Domestically Developed Single-Arm Single-Port Robotic System in Ultra-Remote Telesurgery: A Clinical Report of Two Gynecological Oncology Cases].Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition · 2025Article
- The application of robotic and artificial intelligence technologies in spinal surgery: a review focused on prospects in remote areas of China.Journal of robotic surgery · 2025Review
13 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe purpose of this study was to determine the efficacy and feasibility of 5th generation wireless systems (5G) telerobotic spinal surgery in our first 12 cases.
methodsA total of 12 patients (5 males, 7 females; age, 23-71 years) with spinal disorders (4 thoracolumbar fractures, 6 lumbar spondylolisthesis, 2 lumbar stenosis) were treated with 5G telerobotic spinal surgery. Sixty-two pedicle screws were implanted.
resultsAll patients had substantial relief from their symptoms. Screw placements were classified using Gertzbein-Robbins criteria. There were 59 grade A, 3 grade B. Mean operation time was 142.5 ± 46.7 minutes. Mean guiding wire insertion time was 41.3 ± 9.8 minutes. The deviation between the planned and actual positions was 0.76 ± 0.49 mm. No intraoperative adverse event was found.
conclusion5G remote robot-assisted spinal surgery is accurate and reliable. We conclude that 5G telerobotic spinal surgery is both efficacious and feasible for the management of spinal diseases with safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.