ArticleThe Annals of thoracic surgery2020
Tricuspid Annuloplasty Rings: A Quantitative Comparison of Size, Nonplanar Shape, and Stiffness.
Article in The Annals of thoracic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 19 citations in OpenAlex.
- Effect of Parametric Variation of Chordae Tendineae Structure on Simulated Atrioventricular Valve Closure.Annals of biomedical engineering · 2026Article
- Long-Term Outcomes of Surgical and Transcatheter Interventions for Tricuspid Regurgitation: A Comprehensive Review.Journal of clinical medicine · 2025Review
- Surgical Treatment Strategy of Functional Tricuspid Regurgitation.Reviews in cardiovascular medicine · 2024Review
- Impact of tricuspid annuloplasty device shape and size on valve mechanics-a computational study.JTCVS open · 2024Article
- Geometric data of commercially available tricuspid valve annuloplasty devices.Data in brief · 2024Article
- Septal annular dilation in chronic ovine functional tricuspid regurgitation.The Journal of thoracic and cardiovascular surgery · 2023Article
- Anterior leaflet-oriented tricuspid annuloplasty using a flexible ring for severe tricuspid regurgitation.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2022Article
- Impact of reductive tricuspid ring annuloplasty on right ventricular size, geometry and strain in an ovine model of functional tricuspid regurgitation.Interactive cardiovascular and thoracic surgery · 2022Article
- Tricuspid Annulus Dilation in Patients With Combined Functional Tricuspid Regurgitation and Left-Heart Valvular Disease: Does Septal Annulus Not Dilate?Frontiers in cardiovascular medicine · 2022Article
- Functional Tricuspid Regurgitation: Behind the Scenes of a Long-Time Neglected Disease.Frontiers in cardiovascular medicine · 2022Review
- Commentary: Bespoke tricuspid tailoring-bringing patient-specific valve repair to the forgotten valve.JTCVS techniques · 2021Article
- Diagnosis and Management of Failed Surgical Tricuspid Valve Annuloplasty.Current cardiology reports · 2021Review
- Tricuspid Valve Annuloplasty Alters Leaflet Mechanics.Annals of biomedical engineering · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 2 countries.
Funding
Abstract
backgroundFunctional tricuspid regurgitation due to annular and ventricular dilatation is increasingly recognized as a significant source of morbidity and mortality. To repair the annulus, surgeons implant one of many annuloplasty devices that differ in size, 3-dimensional (3D) shape, and stiffness. However, there have been no quantitative comparisons between various available devices.
methodsThree-dimensional scanning, micro-computed tomography imaging, analytical methods, and mechanical tests were used to compare 3 Edwards Lifesciences (Irvine, CA) and 3 Medtronic (Minneapolis, MN) annuloplasty devices of all available sizes. We measured in-plane metrics of maximum diameter, perimeter, area, height, as well as elevation and curvature profiles. Furthermore, we computed bending stiffness as well as the maximum and minimum axes of the bending stiffness.
resultsMost annular prostheses differed little in their in-plane geometries but varied significantly in height. In-plane properties deviated significantly from measurements of healthy human tricuspid annuli. Height of the Edwards' MC3 and Medtronic's Contour 3D resembled healthy human tricuspid valve annuli, whereas the Edwards' Physio and Classic, and Medtronic's TriAd, did not. Additionally, the elevation profiles of the MC3 and Contour 3D and curvature profiles between all devices were consistent and matched those of healthy human annuli. The tested devices also differed in their bending stiffness, both in terms of absolute values and their maximum and minimum axes.
conclusionsContoured devices, such as Edwards' MC3 and Medtronic's Contour 3D, most accurately resembled the healthy human tricuspid annulus but differed significantly in bending stiffness. To what extent prosthesis properties and shape affect tricuspid valve function remains to be determined.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.