Evidence map›Paper›PMID 32244836›Full record

ArticlePolymers2020

Synthesis of Novel Polymeric Acrylate-Based Flame Retardants Containing Two Phosphorus Groups in Different Chemical Environments and Their Influence on the Flammability of Poly (Lactic Acid).

Jacob Sag, Philipp Kukla, Daniela Goedderz, Hendrik Roch, Stephan Kabasci, Manfred Döring, Frank Schönberger

Abstract read
In one paragraph

Article in Polymers, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jacob SagDepartment of Polymer Synthesis, Fraunhofer Institute for Structural Durability and System Reliability LBF, Schlossgartenstraße 6, D-64289 Darmstadt, Germany.
Philipp KuklaDepartment of Polymer Synthesis, Fraunhofer Institute for Structural Durability and System Reliability LBF, Schlossgartenstraße 6, D-64289 Darmstadt, Germany.
Daniela GoedderzDepartment of Polymer Synthesis, Fraunhofer Institute for Structural Durability and System Reliability LBF, Schlossgartenstraße 6, D-64289 Darmstadt, Germany.
Hendrik RochDepartment of Bio-Based Plastics, Fraunhofer Institute for Environmental, Safety and Energy Technology, UMSICHT, Osterfelder Straße 3, D-46047 Oberhausen, Germany.
Stephan KabasciDepartment of Bio-Based Plastics, Fraunhofer Institute for Environmental, Safety and Energy Technology, UMSICHT, Osterfelder Straße 3, D-46047 Oberhausen, Germany.ORCID 0000-0003-3716-0414
Manfred DöringDepartment of Polymer Synthesis, Fraunhofer Institute for Structural Durability and System Reliability LBF, Schlossgartenstraße 6, D-64289 Darmstadt, Germany.ORCID 0000-0002-7006-9009
Frank SchönbergerDepartment of Polymer Synthesis, Fraunhofer Institute for Structural Durability and System Reliability LBF, Schlossgartenstraße 6, D-64289 Darmstadt, Germany.

Funding

Fraunhofer-Gesellschaft WISA 833 908
6 · The paper itself

Abstract

Novel polymeric acrylate-based flame retardants (FR 1-4) containing two phosphorus groups in different chemical environments were synthesized in three steps and characterized via nuclear magnetic resonance (NMR) spectroscopy, thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and mass spectrometry (MS). Polylactic acid (PLA) formulations with the synthesized compounds were investigated to evaluate the efficiency of these flame retardants and their mode of action by using TGA, UL94, and cone calorimetry. In order to compare the results a flame retardant polyester containing only one phosphorus group (ItaP) was also investigated in PLA regarding its flame inhibiting effect. Since the fire behavior depends not only on the mode of action of the flame retardants but also strongly on physical phenomena like melt dripping, the flame retardants were also incorporated into PLA with higher viscosity. In the UL94 vertical burning test setup, 10% of the novel flame retardants (FR 1-4) is sufficient to reach a V-0 rating in both PLA types, while a loading of 15% of ItaP is not enough to reach the same classification. Despite their different structure, TGA and cone calorimetry results confirmed a gas phase mechanism mainly responsible for the highly efficient flame retardancy for all compounds. Finally, cone calorimetry tests of the flame retardant PLA with two heat fluxes showed different flame inhibiting efficiencies for different fire scenarios.

Indexed as

acrylate-based flame retardantphosphorus-based flame retardantpolylactic acid

Identifiers

PMID32244836
PMCPMC7240360

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.