Automatic intraoperative optical coherence tomography positioning.

Matthias Grimm, Hessam Roodaki, Abouzar Eslami, Nassir Navab

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Matthias GrimmTechnical University of Munich, Garching bei München, Germany. matthias.grimm@tum.de.ORCID http://orcid.org/0000-0002-3433-4020
Hessam RoodakiTechnical University of Munich, Garching bei München, Germany.
Abouzar EslamiTranslational Research Lab, Carl Zeiss Meditec, München, Germany.
Nassir NavabTechnical University of Munich, Garching bei München, Germany.
Carl Zeiss (Germany) · DEJohns Hopkins University · USTechnical University of Munich · DE

Funding

Enabling technology for image-guided robot-assisted sub-retinal injectionsR01EB025883 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI IORDACHITA, IULIAN IOAN · 2019 to 2021
$1.5M
Bundesministerium für Bildung und Forschung 13GW0236BNIBIB NIH HHS R01 EB025883
6 · The paper itself

Abstract

purposeIntraoperative optical coherence tomography (iOCT) was recently introduced as a new modality for ophthalmic surgeries. It provides real-time cross-sectional information at a very high resolution. However, properly positioning the scan location during surgery is cumbersome and time-consuming, as a surgeon needs both his hands for surgery. The goal of the present study is to present a method to automatically position an iOCT scan on an anatomy of interest in the context of anterior segment surgeries.

methodsFirst, a voice recognition algorithm using a context-free grammar is used to obtain the desired pose from the surgeon. Then, the limbus circle is detected in the microscope image and the iOCT scan is placed accordingly in the X-Y plane. Next, an iOCT sweep in Z direction is conducted and the scan is placed to centre the topmost structure. Finally, the position is fine-tuned using semantic segmentation and a rule-based system.

resultsThe logic to position the scan location on various anatomies was evaluated on ex vivo porcine eyes (10 eyes for corneal apex and 7 eyes for cornea, sclera and iris). The mean euclidean distances (± standard deviation) was 76.7 (± 59.2) pixels and 0.298 (± 0.229) mm. The mean execution time (± standard deviation) in seconds for the four anatomies was 15 (± 1.2). The scans have a size of 1024 by 1024 pixels. The method was implemented on a Carl Zeiss OPMI LUMERA 700 with RESCAN 700.

conclusionThe present study introduces a method to fully automatically position an iOCT scanner. Providing the possibility of changing the OCT scan location via voice commands removes the burden of manual device manipulation from surgeons. This in turn allows them to keep their focus on the surgical task at hand and therefore increase the acceptance of iOCT in the operating room.

Indexed as

AlgorithmsAnimalsCross-Sectional StudiesEyeMicroscopyMonitoring, IntraoperativeOphthalmologic Surgical ProceduresSwineTomography, Optical CoherenceAutomatic positioningComputer-aided ophthalmic surgeryIntraoperative optical coherence tomography

Identifiers

PMID32242299
PMCPMC7261282
OpenAlexW3014271215

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.