ArticleJournal of biomedical optics2020
Investigation of the quantification of hemoglobin and cytochrome-c-oxidase in the exposed cortex with near-infrared hyperspectral imaging: a simulation study.
Article in Journal of biomedical optics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 16 citations in OpenAlex.
- Medical hyperspectral imaging: an updated review of technology advancements and biomedical applications.Journal of biomedical optics · 2026Pooled it
- Hyperspectral imaging for tumor resection guidance in surgery: a systematic review of preclinical and clinical studies.Journal of biomedical optics · 2025Pooled it
- Digital instrument simulator to optimize the development of hyperspectral systems: application for intraoperative functional brain mapping.Journal of biomedical optics · 2025Article
- Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications.Journal of biomedical optics · 2025Review
- Learnable real-time inference of molecular composition from diffuse spectroscopy of brain tissue.Journal of biomedical optics · 2024Article
- Review on the Application of Hyperspectral Imaging Technology of the Exposed Cortex in Cerebral Surgery.Frontiers in bioengineering and biotechnology · 2022Review
- Light transport modeling in highly complex tissues using the implicit mesh-based Monte Carlo algorithm.Biomedical optics express · 2021Article
- A hyperspectral imaging system for mapping haemoglobin and cytochrome-c-oxidase concentration changes in the exposed cerebral cortex.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics SocietyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
significanceWe present a Monte Carlo (MC) computational framework that simulates near-infrared (NIR) hyperspectral imaging (HSI) aimed at assisting quantification of the in vivo hemodynamic and metabolic states of the exposed cerebral cortex in small animal experiments. This can be done by targeting the NIR spectral signatures of oxygenated (HbO2) and deoxygenated (HHb) hemoglobin for hemodynamics as well as the oxidative state of cytochrome-c-oxidase (oxCCO) for measuring tissue metabolism.
aimThe aim of this work is to investigate the performances of HSI for this specific application as well as to assess key factors for the future design and operation of a benchtop system. APPROACH: The MC framework, based on Mesh-based Monte Carlo (MMC), reproduces a section of the exposed cortex of a mouse from an in vivo image and replicates hyperspectral illumination and detection at multiple NIR wavelengths (up to 121).
resultsThe results demonstrate: (1) the fitness of the MC framework to correctly simulate hyperspectral data acquisition; (2) the capability of HSI to reconstruct spatial changes in the concentrations of HbO2, HHb, and oxCCO during a simulated hypoxic condition; (3) that eight optimally selected wavelengths between 780 and 900 nm provide minimal differences in the accuracy of the hyperspectral results, compared to the "gold standard" of 121 wavelengths; and (4) the possibility to mitigate partial pathlength effects in the reconstructed data and to enhance quantification of the hemodynamic and metabolic responses.
conclusionsThe MC framework is proved to be a flexible and useful tool for simulating HSI also for different applications and targets.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.