ArticleJournal of applied clinical medical physics2020
The potential of an optical surface tracking system in non-coplanar single isocenter treatments of multiple brain metastases.
Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 27 citations in OpenAlex.
- To shift or not to shift: identifying and correcting patient motion after couch rotations in non-coplanar intracranial radiosurgery with stereoscopic X-ray imaging.Journal of applied clinical medical physics · 2026Article
- The feasibility of using coplanar-only VMAT combined with "Treat" function to replace non-coplanar VMAT for SRS of 2 to 6 brain metastases.Quantitative imaging in medicine and surgery · 2025Article
- Evaluation of the system accuracy of frameless stereotactic radiosurgery using a combination of cone beam CT, six degrees of freedom couch, and surface image-guided systems.Journal of applied clinical medical physics · 2025Article
- Article
- Article
- A prospective randomized study comparing two frameless immobilization systems for cranial stereotactic radiotherapy.Technical innovations & patient support in radiation oncology · 2024Article
- Surface guided radiotherapy practice in paediatric oncology: a survey on behalf of the SIOPE Radiation Oncology Working Group.The British journal of radiology · 2024Article
- Surface guided radiation therapy with an innovative open-face mask and mouth bite: patient motion management in brain stereotactic radiotherapy.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2024Article
- Stereotactic Radiosurgery of Multiple Brain Metastases: A Review of Treatment Techniques.Cancers · 2023Review
- Inpainting truncated areas of CT images based on generative adversarial networks with gated convolution for radiotherapy.Medical & biological engineering & computing · 2023Article
- ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X-ray positioning.Journal of applied clinical medical physics · 2022Article
- Advances and potential of optical surface imaging in radiotherapy.Physics in medicine and biology · 2022Review
- Shift detection discrepancy between ExacTrac Dynamic system and cone-beam computed tomography.Journal of applied clinical medical physics · 2022Article
- Geometrical analysis for motion monitoring of rigid bodies with optical surface scanning in radiation oncology.Physics and imaging in radiation oncology · 2021Article
- Combined effect of dose gradient and rotational error on prescribed dose coverage for single isocenter multiple brain metastases in frameless stereotactic radiotherapy.Radiation oncology (London, England) · 2021Article
- Operation and calibration of the novel PTW 1600SRS detector for the verification of single isocenter stereotactic radiosurgery treatments of multiple small brain metastases.The British journal of radiology · 2021Article
- Evaluation of novel AI-based extended field-of-view CT reconstructions.Medical physics · 2021Article
- Evaluation of technical performance of optical surface imaging system using conventional and novel stereotactic radiosurgery algorithms.Journal of applied clinical medical physics · 2021Article
- A retrospective analysis of setup and intrafraction positional variation in stereotactic radiotherapy treatments.Journal of applied clinical medical physics · 2020Article
- Recent advanced in Surface Guided Radiation Therapy.Radiation oncology (London, England) · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To evaluate the accuracy of a commercial optical surface tracking (OST) system and to demonstrate how it can be implemented to monitor patient positioning during non-coplanar single isocenter stereotactic treatments of brain metastases. A 3-camera OST system was used (Catalyst HD™, C-RAD) on a TruebeamSTx with a 6DoF couch. The setup accuracy and agreement between the OST system, and CBCT and kV-MV imaging at couch angles 0° and 270°, respectively, were examined. Film measurements at 3 depths in the Rando-Alderson phantom were performed using a single isocenter non-coplanar VMAT plan containing 4 brain lesions. Setup of the phantom was performed with CBCT at couch 0° and subsequently monitored by OST at other couch angles. Setup data for 7 volunteers were collected to evaluate the accuracy and reproducibility of the OST system at couch angles 0°, 45°, 90°, 315°, and 270°. These results were also correlated to the couch rotation offsets obtained by a Winston-Lutz (WL) test. The Rando-Alderson phantom, as well as volunteers, were fixated using open face masks (Orfit). For repeated tests with the Rando-Alderson phantom, deviations between rotational and translational isocenter corrections for CBCT and OST systems are always within 0.2° (pitch, roll, yaw), and 0.1mm and 0.5mm (longitudinal, lateral, vertical) for couch positions 0° and 270°, respectively. Dose deviations between the film and TPS doses in the center of the 4 lesions were -1.2%, -0.1%, -0.0%, and -1.9%. Local gamma evaluation criteria of 2%/2 mm and 3%/1 mm yielded pass rates of 99.2%, 99.2%, 98.6%, 89.9% and 98.8%, 97.5%, 81.7%, 78.1% for the 4 lesions. Regarding the volunteers, the mean translational and rotational isocenter shift values were (0.24 ± 0.09) mm and (0.15 ± 0.07) degrees. Largest isocenter shifts were found for couch angles 45˚ and 90˚, confirmed by WL couch rotation offsets. Patient monitoring during non-coplanar VMAT treatments of brain metastases is feasible with submillimeter accuracy.