Evidence map›Paper›PMID 32231232›Full record

ArticleScientific reports2020

Organ ischemia during partial resuscitative endovascular balloon occlusion of the aorta: Dynamic 4D Computed tomography in swine.

Yosuke Matsumura, Akiko Higashi, Yoshimitsu Izawa, Shuji Hishikawa, Hiroshi Kondo, Viktor Reva, Shigeto Oda, Junichi Matsumoto

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Ultrasound assessment is useful for evaluating balloon volume of resuscitative endovascular balloon occlusion of the aorta.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Yosuke MatsumuraDepartment of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, Chiba, Chiba, Japan. yousuke.jpn4035@gmail.com.
Akiko HigashiDepartment of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, Chiba, Chiba, Japan.
Yoshimitsu IzawaDepartment of Emergency and Critical Care Medicine, Saiseikai Utsunomiya Hospital, Utsunomiya, Tochigi, Japan.
Shuji HishikawaCenter for Development of Advanced Medical Technology, Jichi Medical University, Shimotsuke, Tochigi, Japan.
Hiroshi KondoDepartment of Radiology, Teikyo University School of Medicine, Itabashi, Tokyo, Japan.
Viktor RevaDepartment of War Surgery, Kirov Military Medical Academy, Ulitsa Akademika Lebedeva, St Petersburg, Russia.
Shigeto OdaDepartment of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, Chiba, Chiba, Japan.
Junichi MatsumotoDepartment of Emergency and Critical Care Medicine, St. Marianna University School of Medicine, Kawasaki, Kanagawa, Japan.
Chiba University · JPJichi Medical University · JPS. M. Kirov Military Medical Academy · RUSt. Marianna University School of Medicine · JPTeikyo University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Resuscitative endovascular balloon occlusion of the aorta (REBOA) increases proximal pressure, and simultaneously induces distal ischemia. We aimed to evaluate organ ischemia during partial REBOA (P-REBOA) with computed tomography (CT) perfusion in a swine model. The maximum balloon volume was recorded as total REBOA when the distal pulse pressure ceased. The animals (n = 4) were scanned at each 20% of the maximum balloon volume, and time-density curve (TDC) were analysed at the aorta, portal vein (PV), liver parenchyma, and superior mesenteric vein (SMV, indicating mesenteric perfusion). The area under the TDC (AUTDC), the time to peak (TTP), and four-dimensional volume-rendering images (4D-VR) were evaluated. The TDC of the both upper and lower aorta showed an increased peak and delayed TTP. The TDC of the PV, liver, and SMV showed a decreased peak and delayed TTP. The dynamic 4D-CT analysis suggested that organ perfusion changes according to balloon volume. The AUTDC at the PV, liver, and SMV decreased linearly with balloon inflation percentage to the maximum volume. 4D-VR demonstrated the delay of the washout in the aorta and retrograde flow at the inferior vena cava in the highly occluded status.

Indexed as

AnimalsAortaBalloon OcclusionBlood PressureDisease Models, AnimalEndovascular ProceduresFemaleFour-Dimensional Computed TomographyHemodynamicsIschemiaLiverMesenteric VeinsPortal VeinResuscitationSwineVena Cava, Inferior

Identifiers

PMID32231232
PMCPMC7105501
OpenAlexW3013328766

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.