Evidence map›Paper›PMID 32229316›Full record

ArticleBiophysical journal2020

The Kinesin-8 Kip3 Depolymerizes Microtubules with a Collective Force-Dependent Mechanism.

Michael Bugiel, Mayank Chugh, Tobias Jörg Jachowski, Erik Schäffer, Anita Jannasch

Open access · bronzeAbstract read
In one paragraph

Article in Biophysical journal, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 14 citations in OpenAlex.

  1. Modeling study of kinesin-13 MCAK microtubule depolymerase.European biophysics journal : EBJ · 2024
    Article
  2. Article
  3. Article
  4. Review
  5. Atomic force microscopy reveals distinct protofilament-scale structural dynamics in depolymerizing microtubule arrays.Proceedings of the National Academy of Sciences of the United States of America · 2022
    Article
  6. Article
  7. STAR protocols · 2020
    Article
  8. Microtubules regulate cardiomyocyte transversal Young's modulus.Proceedings of the National Academy of Sciences of the United States of America · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Michael BugielCellular Nanoscience, Center for Plant Molecular Biology (ZMBP), University of Tübingen, Tübingen, Germany.
Mayank ChughCellular Nanoscience, Center for Plant Molecular Biology (ZMBP), University of Tübingen, Tübingen, Germany.
Tobias Jörg JachowskiCellular Nanoscience, Center for Plant Molecular Biology (ZMBP), University of Tübingen, Tübingen, Germany.
Erik SchäfferCellular Nanoscience, Center for Plant Molecular Biology (ZMBP), University of Tübingen, Tübingen, Germany. Electronic address: erik.schaeffer@uni-tuebingen.de.
Anita JannaschCellular Nanoscience, Center for Plant Molecular Biology (ZMBP), University of Tübingen, Tübingen, Germany. Electronic address: anita.jannasch@uni-tuebingen.de.
University of Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microtubules are highly dynamic filaments with dramatic structural rearrangements and length changes during the cell cycle. An accurate control of the microtubule length is essential for many cellular processes, in particular during cell division. Motor proteins from the kinesin-8 family depolymerize microtubules by interacting with their ends in a collective and length-dependent manner. However, it is still unclear how kinesin-8 depolymerizes microtubules. Here, we tracked the microtubule end-binding activity of yeast kinesin-8, Kip3, under varying loads and nucleotide conditions using high-precision optical tweezers. We found that single Kip3 motors spent up to 200 s at the microtubule end and were not stationary there but took several 8-nm forward and backward steps that were suppressed by loads. Interestingly, increased loads, similar to increased motor concentrations, also exponentially decreased the motors' residence time at the microtubule end. On the microtubule lattice, loads also exponentially decreased the run length and time. However, for the same load, lattice run times were significantly longer compared to end residence times, suggesting the presence of a distinct force-dependent detachment mechanism at the microtubule end. The force dependence of the end residence time enabled us to estimate what force must act on a single motor to achieve the microtubule depolymerization speed of a motor ensemble. This force is higher than the stall force of a single Kip3 motor, supporting a collective force-dependent depolymerization mechanism that unifies the so-called "bump-off" and "switching" models. Understanding the mechanics of kinesin-8's microtubule end activity will provide important insights into cell division with implications for cancer research.

Indexed as

KinesinsSaccharomyces cerevisiae ProteinsMechanical PhenomenaMicrotubulesSaccharomyces cerevisiaeKinesinsKIP3 protein, S cerevisiaeSaccharomyces cerevisiae Proteins

Identifiers

PMID32229316
PMCPMC7175476
OpenAlexW3010972328

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.