Evidence map›Paper›PMID 32219989›Full record

ArticleJournal of medical radiation sciences2020

Evaluation of an integrated 3D-printed phantom for coronary CT angiography using iterative reconstruction algorithm.

Kamarul A Abdullah, Mark F McEntee, Warren Reed, Peter L Kench

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Journal of medical radiation sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Kamarul A AbdullahFaculty of Health Sciences, Universiti Sultan Zainal Abidin, Terengganu, Malaysia.ORCID https://orcid.org/0000-0002-3568-9579
Mark F McEnteeDiscipline of Medical Radiation Sciences, Faculty of Health Sciences, The University of Sydney, Lidcombe, New South Wales, Australia.ORCID https://orcid.org/0000-0001-7045-2190
Warren ReedDiscipline of Medical Radiation Sciences, Faculty of Health Sciences, The University of Sydney, Lidcombe, New South Wales, Australia.ORCID https://orcid.org/0000-0002-8937-2198
Peter L KenchDiscipline of Medical Radiation Sciences, Faculty of Health Sciences, The University of Sydney, Lidcombe, New South Wales, Australia.ORCID https://orcid.org/0000-0002-4327-0321
The University of Sydney · AUSultan Zainal Abidin University · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction3D-printed imaging phantoms are now increasingly available and used for computed tomography (CT) dose optimisation study and image quality analysis. The aim of this study was to evaluate the integrated 3D-printed cardiac insert phantom when evaluating iterative reconstruction (IR) algorithm in coronary CT angiography (CCTA) protocols.

methodsThe 3D-printed cardiac insert phantom was positioned into a chest phantom and scanned with a 16-slice CT scanner. Acquisitions were performed with CCTA protocols using 120 kVp at four different tube currents, 300, 200, 100 and 50 mA (protocols A, B, C and D, respectively). The image data sets were reconstructed with a filtered back projection (FBP) and three different IR algorithm strengths. The image quality metrics of image noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were calculated for each protocol.

resultsDecrease in dose levels has significantly increased the image noise, compared to FBP of protocol A (P < 0.001). As a result, the SNR and CNR were significantly decreased (P < 0.001). For FBP, the highest noise with poor SNR and CNR was protocol D with 19.0 ± 1.6 HU, 18.9 ± 2.5 and 25.1 ± 3.6, respectively. For IR algorithm, the highest strength (AIDR3D

conclusionsThe use of IR algorithm and increasing its strengths have reduced noise significantly and thus increased the SNR and CNR when compared to FBP. Therefore, this integrated 3D-printed phantom approach could be used for dose optimisation study and image quality analysis in CCTA protocols.

Indexed as

AlgorithmsComputed Tomography AngiographyCoronary AngiographyPhantoms, ImagingPrinting, Three-DimensionalImage Processing, Computer-AssistedRadiation DosageSignal-To-Noise Ratiocoronary CTAdose optimisationimage qualityphantomreconstruction settings

Identifiers

PMID32219989
PMCPMC7476188
OpenAlexW3013547159

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.