Evidence map›Paper›PMID 32215660›Full record

ArticleEuropean journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery2020

Pacemaker implantation after aortic valve replacement: rapid-deployment Intuity® compared to conventional bioprostheses.

Morgane Herry, Driss Laghlam, Olivier Touboul, Lee S Nguyen, Philippe Estagnasié, Alain Brusset, Pierre Squara

Open access · bronzeAbstract read
In one paragraph

Article in European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Morgane HerryDepartment of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Driss LaghlamDepartment of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Olivier TouboulDepartment of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Lee S NguyenDepartment of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Philippe EstagnasiéDepartment of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Alain BrussetDepartment of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Pierre SquaraDepartment of Cardiology and Critical Care, Clinique Ambroise Paré, Neuilly-sur-Seine, France.
Clinique Ambroise Paré · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe aim of this study was to compare the incidence of permanent pacemaker (PPM) implantation after aortic valve replacement by rapid-deployment bioprosthesis (RDB) and standard valve (Standard).

methodsAll patients undergoing aortic valve replacement between 2015 and 2018, in 1 centre, were included. A multivariate analysis on the whole cohort and then a propensity score matching were used to compare the 2 groups. The primary end point was PPM implantation.

resultsWe studied 924 patients (256 RDBs and 668 Standards). Overall, 67 PPM were implanted, 37 (14.5%) in the RDB group and 26 (3.9%) in the Standard group (P < 0.0001, univariate analysis). The multivariate analysis in the unmatched population found 4 independent factors associated with PPM implantation: right bundle branch block with odds ratios (ORs 3.7, 95% CI 2.9-6.7; P < 0.0001), RDB (OR 3.6, 95% CI 2.0-6.2; P < 0.0001), age (OR 1.1, 95% CI 1.0-1.1; P < 0.006) and endocarditis (OR 3.4, 95% CI 1.0-11.0; P < 0.04). In the propensity score-matched RDB group (203 patients per group), 25 patients required PPM implantation versus 3 in the Standard group (12.3% vs 1.5%, P < 0.0001). RDBs also had more postoperative left bundle branch block and new onset of atrial fibrillation (30.2% vs 5.1%, P < 0.0001 and 34.0% vs 24.1%, P = 0.029). RDBs had lower operating times (in min): aortic cross-clamping = 62 (44-76.5) vs 72 (57.5-91.5) and cardiopulmonary bypass = 81 (63-98.5) vs 91 (75-112), P < 0.0001. There was no significant difference in other outcomes.

conclusionsRDBs were associated with reduced operating times, increased risk of atrial fibrillation and PPM implantation as compared with standard aortic valves.

Indexed as

Aortic Valve StenosisBioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationPacemaker, ArtificialAortic ValveHumansRetrospective StudiesRisk FactorsTreatment OutcomeAortic valve replacementCardiac surgeryPacemaker implantationRapid-deployment bioprosthesis

Identifiers

PMID32215660
PMCPMC7373323
OpenAlexW3013164706

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.