Evidence map›Paper›PMID 32211590›Full record

ArticleJOR spine2020

Load-transfer in the human vertebral body following lumbar total disc arthroplasty: Effects of implant size and stiffness in axial compression and forward flexion.

Noah B Bonnheim, Tony M Keaveny

Open access · goldAbstract read
In one paragraph

Article in JOR spine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Noah B BonnheimDepartment of Mechanical Engineering University of California Berkeley California.ORCID https://orcid.org/0000-0003-2191-180X
Tony M KeavenyDepartment of Mechanical Engineering University of California Berkeley California.
University of California, Berkeley · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Adverse clinical outcomes for total disc arthroplasty (TDA), including subsidence, heterotopic ossification, and adjacent-level vertebral fracture, suggest problems with the underlying biomechanics. To gain insight, we investigated the role of size and stiffness of TDA implants on load-transfer within a vertebral body. Uniquely, we accounted for the realistic multi-scale geometric features of the trabecular micro-architecture and cortical shell. Using voxel-based finite element analysis derived from a micro-computed tomography scan of one human L1 vertebral body (74-μm-sized elements), a series of generic elliptically shaped implants were analyzed. We parametrically modeled three implant sizes (small, medium [a typical clinical size], and large) and three implant materials (metallic, E = 100 GPa; polymeric, E = 1 GPa; and tissue-engineered, E = 0.01 GPa). Analyses were run for two load cases: 800 N in uniform compression and flexion-induced anterior impingement. Results were compared to those of an intact model without an implant and loaded instead via a disc-like material. We found that TDA implantation increased stress in the bone tissue by over 50% in large portions of the vertebra. These changes depended more on implant size than material, and there was an interaction between implant size and loading condition. For the small implant, flexion increased the 98th-percentile of stress by 32 ± 24% relative to compression, but the overall stress distribution and trabecular-cortical load-sharing were relatively insensitive to loading mode. In contrast, for the medium and large implants, flexion increased the 98th-percentile of stress by 42 ± 9% and 87 ± 29%, respectively, and substantially re-distributed stress within the vertebra; in particular overloading the anterior trabecular centrum and cortex. We conclude that TDA implants can substantially alter stress deep within the lumbar vertebra, depending primarily on implant size. For implants of typical clinical size, bending-induced impingement can substantially increase stress in local regions and may therefore be one factor driving subsidence in vivo.

Indexed as

biomechanicsfinite element analysisimpingementsubsidencetotal disc arthroplastytotal disc replacement

Identifiers

PMID32211590
PMCPMC7084059
OpenAlexW3000444399

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.