Evidence map›Paper›PMID 32211565›Full record

ArticleBioactive materials2020

Enhanced physicochemical and biological properties of C/Cu dual ions implanted medical titanium.

Chao Xia, Xiaohan Ma, Xianming Zhang, Kunqiang Li, Ji Tan, Yuqin Qiao, Xuanyong Liu

Open access · goldAbstract read
In one paragraph

Article in Bioactive materials, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
6.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 71 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Review
  12. Review
  13. Article
  14. Review
  15. Recent Advances in Copper-Doped Titanium Implants.Materials (Basel, Switzerland) · 2022
    Review
  16. Application of Copper Nanoparticles in Dentistry.Nanomaterials (Basel, Switzerland) · 2022
    Review
  17. Review
  18. Review
  19. Biomedical Implants with Charge-Transfer Monitoring and Regulating Abilities.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Chao XiaState Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Xiaohan MaState Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Xianming ZhangState Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Kunqiang LiState Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Ji TanState Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Yuqin QiaoState Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Xuanyong LiuState Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
Chinese Academy of Sciences · CNShanghai Institute of Ceramics · CNShanghai Normal University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

It is increasingly popular for titanium and its alloys to be utilized as the medical implants. However, their bio-inert nature and lack of antibacterial ability limit their applications. In this work, by utilizing plasma immersion ion implantation and deposition (PIII&D) technology, the titanium surface was modified by C/Cu co-implantation. The mechanical property, corrosion resistance, antibacterial ability and cytocompatibility of modified samples were studied. Results indicate that after C/Cu co-implantation, copper nanoparticles were observed on the surface of titanium, and titanium carbide existed on the near surface region of titanium. The modified surface displayed good mechanical property and corrosion resistance. The Cu/C galvanic corrosion existed on the titanium surface implanted by C/Cu dual ions, and release of copper ions can be effectively controlled by the galvanic corrosion effect. Moreover, improved antibacterial performance of titanium surface can be achieved without cytotoxicity.

Indexed as

Antibacterial abilityCarbonCopperIon implantationTitanium

Identifiers

PMID32211565
PMCPMC7083793
OpenAlexW3011622475

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.