ArticleInternational journal of nanomedicine2020
Surface Functionalization with Proanthocyanidins Provides an Anti-Oxidant Defense Mechanism That Improves the Long-Term Stability and Osteogenesis of Titanium Implants.
Article in International journal of nanomedicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 31 citations in OpenAlex.
- Metabolomic analysis reveals flavonoid accumulation patterns in four apricot cultivars.Food chemistry: X · 2026Article
- Proanthocyanidins Alleviate T-2 Toxin-Induced Toxicity in Yak (Antioxidants (Basel, Switzerland) · 2026Article
- Recombinant Human SLPI Surface Functionalization Enhances Early Osseointegration and Biomechanical Stability of Titanium Implants in Rat Model.Journal of functional biomaterials · 2026Article
- Recent advances in layer-by-layer assembly scaffolds for co-delivery of bioactive molecules for bone regeneration: an updated review.Journal of translational medicine · 2024Review
- Article
- Evaluation of sustained drug release performance and osteoinduction of magnetron-sputtered tantalum-coated titanium dioxide nanotubes.RSC advances · 2024Article
- Surface-modified titanium and titanium-based alloys for improved osteogenesis: A critical review.Heliyon · 2024Review
- Engineering Antioxidant Surfaces for Titanium-Based Metallic Biomaterials.Journal of functional biomaterials · 2023Review
- Progress in Surface Modification of Titanium Implants by Hydrogel Coatings.Gels (Basel, Switzerland) · 2023Review
- Construction of Local Drug Delivery System on Titanium-Based Implants to Improve Osseointegration.Pharmaceutics · 2022Review
- High proportion strontium-doped micro-arc oxidation coatings enhance early osseointegration of titanium in osteoporosis by anti-oxidative stress pathway.Bioactive materials · 2022Article
- Titanium with nanotopography attenuates the osteoclast-induced disruption of osteoblast differentiation by regulating histone methylation.Biomaterials advances · 2022Article
- The progress in titanium alloys used as biomedical implants: From the view of reactive oxygen species.Frontiers in bioengineering and biotechnology · 2022Review
- Advanced Surface Modification for 3D-Printed Titanium Alloy Implant Interface Functionalization.Frontiers in bioengineering and biotechnology · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeAseptic loosening is a major complication after total joint replacement. Reactive oxygen species generated by local tissue cells and liberated from implant surfaces have been suggested to cause implant failures. Surface modification of titanium (Ti)-based implants with proanthocyanidins (PAC) is a promising approach for the development of anti-oxidant defense mechanism to supplement the mechanical functions of Ti implants. In this study, a controlled PAC release system was fabricated on the surface of Ti substrates using the layer-by-layer (LBL) assembly. MATERIALS AND
methodsPolyethyleneimine (PEI) base layer was fabricated to enable layer-by-layer (LBL) deposition of hyaluronic acid/chitosan (HA/CS) multi-layers without or with the PAC. Surface topography and wettability of the fabricated HA/CS-PAC substrates were characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), Fourier-transform infrared spectroscopy (FTIR) and contact angle measurement. PAC release profiles were investigated using drug release assays. MC3T3-E1 pre-osteoblast cells were used to assess the osteo-inductive effects of HA/CS-PAC substrates under conditions H
resultsSEM, AFM, FTIR and contact angle measurements verified the successful fabrication of Ti surfaces with multi-layered HA/CS-PAC coating. Drug release assays revealed controlled and sustained release of PAC over 14 days. In vitro, cell-based assays showed high tolerability and enhanced the osteogenic potential of MC3T3-E1 cells on HA/CS-PAC substrates when under conditions of H
conclusionMulti-layering of HA/CS-PAC coating onto Ti-based surfaces by the LBL deposition significantly enhances implant osseo-integration and promotes osteogenesis under conditions of oxidative stress. This study provides new insights for future applications in the field of joint arthroplasty.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.