Evidence map›Paper›PMID 32209528›Full record

ArticleJMIR medical informatics2020

Real-Time Streaming of Surgery Performance and Intraoperative Imaging Data in the Hybrid Operating Room: Development and Usability Study.

Chun-Cheng Lin, Yu-Pin Chen, Chao-Ching Chiang, Ming-Chau Chang, Oscar Kuang-Sheng Lee

Open access · goldAbstract read
In one paragraph

Article in JMIR medical informatics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Chun-Cheng LinInstitute of Clinical Medicine, National Yang-Ming University, Taipei, Taiwan.ORCID https://orcid.org/0000-0002-7386-7487
Yu-Pin ChenDepartment of Orthopedic Surgery, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.ORCID https://orcid.org/0000-0002-9729-6375
Chao-Ching ChiangDivision of Orthopaedic Trauma, Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.ORCID https://orcid.org/0000-0002-9889-3294
Ming-Chau ChangDepartment of Surgery, National Yang-Ming University, Taipei, Taiwan.ORCID https://orcid.org/0000-0003-2423-1471
Oscar Kuang-Sheng LeeInstitute of Clinical Medicine, National Yang-Ming University, Taipei, Taiwan.ORCID https://orcid.org/0000-0001-5232-5374
National Yang Ming Chiao Tung University · TWWan Fang Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe trend of quick evolution and increased digital data in today's operating rooms (ORs) has led to the construction of hybrid ORs. There is often a main control room with monitors for integrating intraoperative data from multiple devices in the hybrid OR. However, there is no adequate solution for communicating the data with people outside the OR.

objectiveThe objective of this study was to design an intelligent operating room (iOR) system, augmented onto the existing information technology (IT) infrastructure of hybrid ORs, to stream surgery performance and intraoperative imaging data.

methodsIn this study, an all-in-one device with synergetic encoder and decoder was used. The device was able to stream multiple sources to one display. The lossless video and images from specific surgical workflows were streamed outside the hybrid OR through network protocols and were further managed by a streaming server and wireless control system. The steps of this study included the following: (1) defining the requirements and feasibility of an iOR system in the hybrid OR, (2) connecting multiple sources, (3) setting up equipment across the hybrid OR and a conference room, (4) designing a video management system, and (5) real-time streaming under specific surgical workflows.

resultsThe wired streamed video was shown simultaneously on the display in the hybrid OR and the display in the conference room with near-zero latency. Additionally, an interactive video between the hybrid OR and the conference room was achieved through the bidirectional wireless control system. The functions of recording, archiving, and playback were successfully provided by the streaming server. The readily available hardware components and open-access programming reduced the cost required to construct this streaming system.

conclusionsThis flexible and cost-effective iOR system not only provided educational benefits, but also contributed to surgical telementoring.

Indexed as

encoder and decoderhybrid operating roominformation technologyinformation technology infrastructuremedical imagingoperating roomreal-time streamingreal-world evidencesurgerysurgical telementoring

Identifiers

PMID32209528
PMCPMC7316181
OpenAlexW3013004666

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.