ArticlePhysiological reports2020
Application of the optimized carbon monoxide rebreathing method for the measurement of total haemoglobin mass in chronic liver disease.
Article in Physiological reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 10 citations in OpenAlex.
- Stability of carboxy-hemoglobin during storage at different temperatures.Drug testing and analysis · 2025Article
- Clinical importance of distinguishing true anemia from dilutional pseudo-anemia: Consequences of a 3-year follow-up volume assessment in a heart failure patient.Clinical case reports · 2024Article
- Cardiopulmonary exercise testing before and after intravenous iron in preoperative patients: a prospective clinical study.Perioperative medicine (London, England) · 2023Article
- Blood volume and hemoglobin mass in long-term heart transplant recipients with and without Anemia.Journal of cardiothoracic surgery · 2021Article
- Letter to the editor: "Comment on: Application of the optimized carbon monoxide rebreathing method for the measurement of total haemoglobin mass in chronic liver disease".Physiological reports · 2020Article
- Application of the optimized carbon monoxide rebreathing method for the measurement of total haemoglobin mass in chronic liver disease.Physiological reports · 2020Article
Corrections and comments
- Commented on by
Authors and funding
7 authors at 6 institutions in 3 countries.
Funding
Abstract
backgroundAnemia is common in liver cirrhosis. This generally infers a fall in total hemoglobin mass (tHb-mass). However, hemoglobin concentration ([Hb]) may fall due to an expansion in plasma volume (PV). The "optimized carbon monoxide rebreathing method" (oCOR) measures tHb-mass directly and PV (indirectly using hematocrit). It relies upon carboxyhemoglobin (COHb) distribution throughout the entire circulation. In healthy subjects, such distribution is complete within 6-8 min. Given the altered circulatory dynamics in cirrhosis, we sought in this pilot study, to assess whether this was true in cirrhosis. The primary aim was to ascertain if the standard timings for the oCOR were applicable to patients with chronic liver disease and cirrhosis. The secondary aim was to explore the applicability of standard CO dosing methodologies to this patient population.
methodsSixteen patients with chronic liver parenchymal disease were studied. However, tHb-mass was determined using the standard oCOR technique before elective paracentesis. Three subjects had an inadequate COHb% rise. In the remaining 13 (11 male), mean ± standard deviation (SD) age was 52 ± 13.8 years, body mass 79.1 ± 11.4 kg, height 175 ± 6.8 cm. To these, mean ± SD dose of carbon monoxide (CO) gas administered was 0.73 ± 0.13 ml/kg COHb values at baseline, 6 and 8 min (and "7-min value") were compared to those at 10, 12, 15 and 20 min after CO rebreathing.
resultsThe "7-min value" for median COHb% (IQR) of 6.30% (6.21%-7.47%) did not differ significantly from those at subsequent time points (8 min: 6.30% (6.21%-7.47%), 10 min: 6.33% (6.00%-7.50%), 12 min: 6.33% (5.90%-7.40%), 15 min: 6.37% (5.80%-7.33%), 20 min: 6.27% (5.70%-7.20%)). Mean difference in calculated tHb-mass between minute 7 and minute 20 was only 4.1 g, or 0.6%, p = .68. No subjects reported any adverse effects.
conclusionsThe oCOR method can be safely used to measure tHb-mass in patients with chronic liver disease and ascites, without adjustment of blood sample timings. Further work might refine and validate appropriate dosing regimens.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.