Evidence map›Paper›PMID 32206985›Full record

ArticleLa Radiologia medica2020

Clinical and histopathological outcome of cervical and chest MRI involving non-MRI-conditional cardiac pacemakers: a study using sheep models.

Shadi Daghighi, Aimee Chan, Ali Kiani Nazarlou, Zeinab Hasan, Monireh Halimi, Fariborz Akbarzadeh, Davoud Kazemi, Mohammad Hossein Daghighi, Daniel Fadaei Fouladi

Abstract read
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 3 countries.

Shadi DaghighiDepartment of Radiology, University of California, San Diego, CA, USA.
Aimee ChanDepartment of Radiology, University of Toronto (Sunnybrook), Toronto, Ontario, Canada.
Ali Kiani NazarlouDepartment of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran.
Zeinab HasanDepartment of Pathology, University of Tennessee, Memphis, TN, USA.
Monireh HalimiDepartment of Pathology, Tabriz University of Medical Sciences, Tabriz, Iran.
Fariborz AkbarzadehDepartment of Cardiology, Tabriz University of Medical Sciences, Tabriz, Iran.
Davoud KazemiDepartment of Veterinary Clinical Sciences, Faculty of Veterinary Medicine Tabriz Branch, Islamic Azad University, Tabriz, Iran.ORCID https://orcid.org/0000-0001-5522-8035
Mohammad Hossein DaghighiDepartment of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran.
Daniel Fadaei FouladiNeurosciences Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Dfoulad1@jhmi.edu.
Tabriz University of Medical Sciences · IRIslamic Azad University of Tabriz · IRSunnybrook Health Science Centre · CAUniversity of California San Diego · USUniversity of Tennessee Health Science Center · US

Funding

Tabriz University of Medical Sciences 5188
6 · The paper itself

Abstract

aimTo examine the clinical and histopathological consequences of MRI in sheep implanted with non-MRI-conditional cardiac pacemakers. MATERIALS AND

methodsUnder general anesthesia, active fixation leads of two dual-chamber, non-MRI-conditional cardiac pacemakers (St. Jude Medical and Medtronic) were implanted either at the right ventricular apex or at the right atrium of two male sheep and connected to the V and A channels of the pacemakers, respectively. The generators were placed in cervical subcutaneous pockets. On day 5, both sheep underwent 1.5 T cervical and chest MRI with continuous electrocardiogram monitoring. Obtained sequences were T1-weighted (T1W), T2-weighted (T2W), T2-gradient echo and diffusion weighted (DW). The employed modes were OVO, VOO and VVI for one sheep and OAO, AOO and AAI for the other (unipolar and bipolar configuration of pacing and sensing for both). Battery impedance, pacing lead impedance, intrinsic amplitude and capture thresholds were checked at baseline and after each sequence, as well as 48 h after imaging. Histopathological examination of the cardiac tissue around the lead tip was performed 4 weeks post-imaging.

resultsNo significant changes in device position or configuration were observed during or after MRI. Clinical outcome was uneventful in both sheep. Minor inflammatory and necrotic changes were reported after histopathological examination of the cardiac tissue around the lead tip.

conclusion1.5 T MRI of two implanted non-MRI-conditional pacemakers was found safe in terms of device configuration and stability, clinical outcome and cardiac tissue histopathological findings.

Indexed as

Equipment SafetyPacemaker, ArtificialAnimalsCardiac-Gated Imaging TechniquesDiffusion Magnetic Resonance ImagingMagnetic Resonance ImagingMaleNecrosisProsthesis ImplantationSheepHistopathologyMRINon-MRI-conditional pacemakersSafety

Identifiers

PMID32206985
OpenAlexW3012835359

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.