ArticleJSLS : Journal of the Society of Laparoendoscopic Surgeons
Robotic Fundoplication for Large Paraesophageal Hiatal Hernias.
Article in JSLS : Journal of the Society of Laparoendoscopic Surgeons. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 4 syntheses or guidelines pooled it.
- Adults undergoing robotic hiatal hernia repair: do surgical and patient factors predict 5-year revision? A systematic review.Surgical endoscopy · 2026Pooled it
- Efficacy and safety of mesh reinforced cruroplasty with Phasix™ ST vs. Bio-AHernia : the journal of hernias and abdominal wall surgery · 2026Pooled it
- Hiatal hernia repair with biosynthetic mesh reinforcement: a qualitative systematic review.Surgical endoscopy · 2023Pooled it
- Robotic versus Laparoscopic Hiatal Hernia Repair in Elderly Patients.JSLS : Journal of the Society of Laparoendoscopic SurgeonsPooled it
- The Importance of Gastropexy in Minimally Invasive Hiatal Hernia Repair.Life (Basel, Switzerland) · 2026Article
- Evaluating the Role of PhasixST™ Mesh in Laparoscopic Repair of Large Hiatal Hernias: Surgical Technique and Comprehensive Review of the Literature.Journal of clinical medicine · 2025Review
- A standardized robot-assisted technique for giant paraesophageal hernia repair: the relationship between surgical details and low recurrence rate in long-term follow-up.Langenbeck's archives of surgery · 2025Observational
- Case report: A novel technique of robotic low-tension hiatal hernia repair using mediastinoplication.MethodsX · 2025Article
- Voluminous hiatal hernias - the role of robotic surgery.Innovative surgical sciences · 2025Review
- Robotic hiatal hernia repair without mesh.Journal of thoracic disease · 2024Article
- Robotic-assisted versus laparoscopic paraesophageal hernia repair: a systematic review and meta-analysis.Journal of minimally invasive surgery · 2023Article
- Economic evaluation of robotic and laparoscopic paraesophageal hernia repair.Surgical endoscopy · 2023Article
- Gastric Outlet Obstruction Caused by Acute Gastric Volvulus: A Rare Complication of Hiatal Hernia.Cureus · 2023Article
- Large hiatus hernia: time for a paradigm shift?BMC surgery · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeLaparoscopic fundoplication is now a cornerstone in the treatment of gastro-esophageal reflux disease (GERD) with sliding hernia. The best outcomes are achieved in those patients who have some response to medical treatment compared to those who do not. Robotic fundoplication is considered a novel approach in treating GERD with large paraesophageal hiatal hernias. Our goal was to examine the feasibility of this technique.
methodsSeventy patients (23 males and 47 females) with mean age 64 y old (22-92), preoperatively diagnosed with a large paraesophageal hiatal hernia, were treated with a robotic approach. Biosynthetic tissue absorbable mesh was applied for hiatal closure reinforcement. Fifty-eight patients underwent total fundoplication, 11 patients had partial fundoplication, and one patient had a Collis-Nissen fundoplication for acquired short esophagus.
resultsAll procedures were completed robotically, without laparoscopic or open conversion. Mean operative time was 223 min (180-360). Mean length of stay was 38 h (24-96). Median follow-up was 29 mo (7-51). Moderate postoperative dysphagia was noted in eight patients, all of which resolved after 3 mo without esophageal dilation. No mesh-related complications were detected. There were six hernia recurrences. Four patients were treated with redo-robotic fundoplication, and two were treated medically.
conclusionsThe success of robotic fundoplication depends on adhering to a few important technical principles. In our experience, the robotic surgical treatment of gastroesophageal reflux disease with large paraesophageal hernias may afford the surgeon increased dexterity and is feasible with comparable outcomes compared with traditional laparoscopic approaches.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.