ArticleEar and hearing
Frequency-to-Place Mismatch: Characterizing Variability and the Influence on Speech Perception Outcomes in Cochlear Implant Recipients.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 57 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Relationship Between Pitch Discrimination, Music Abilities and Emotional Speech Perception in School Aged Children With Cochlear Implant
Impact of Anatomy-Based Frequency (ABF) Allocations on Early Performance Outcomes in MED-EL Cochlear Implant Recipients
Who cites it
57 citing papers in PubMed, 1 synthesis or guideline pooled it, 117 citations in OpenAlex.
- Tonotopic versus conventional frequency mapping in adult cochlear implant recipients: a systematic review and meta-analysis of randomized trials.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026Pooled it
- Hearing outcomes following cochlear implantation with anatomic or default frequency mapping in postlingual deafness adults.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024Trial
- Influence of Electric Frequency-to-Place Mismatches on the Early Speech Recognition Outcomes for Electric-Acoustic Stimulation Users.American journal of audiology · 2023Trial
- Benefits of Cochlear Implantation in Childhood Unilateral Hearing Loss (CUHL Trial).The Laryngoscope · 2022Trial
- Long-Term Influence of Electrode Array Length on Speech Recognition in Cochlear Implant Users.The Laryngoscope · 2021Trial
- Cochlear Implantation in Cases of Asymmetric Hearing Loss: Subjective Benefit, Word Recognition, and Spatial Hearing.Trends in hearingTrial
- Outcomes of anatomy based planning in cochlear implantation: a meta-analysis of advancing precision otologic medicine.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026Review
- Attrition in Cochlear Implant Research: Sociodemographic, Audiologic, and Performance Variables.The Laryngoscope · 2026Article
- Angular Insertion Depth for Cochlear Implantation: A Comparative Analysis on Precision of CT, MRI, and x-Ray.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026Article
- Extending the Indications of Cochlear Implantation in Adults with Single-Sided Deafness. A Comprehensive Review.Journal of personalized medicine · 2026Review
- The cochlear morphometry compendium: High-resolution synchrotron measurements and normative reference values.Journal of anatomy · 2026Article
- Longitudinal Correlation of Frequency-to-Place Mismatch and Postoperative Speech Perception Outcomes in Cochlear Implant Recipients: Monosyllable, Consonant, Word, and Sentence.Audiology research · 2026Article
- Review
- Personalizing Cochlear Implant Care in Single-Sided Deafness: A Distinct Paradigm from Bilateral Hearing Loss.Journal of personalized medicine · 2025Review
- Enhancing Musical Experiences for Cochlear Implant Users: Insights From the 2024 International Fall Cochlear Implant Meeting.Otology & neurotology open · 2025Article
- Influence of cochlear coverage on speech perception in single sided deafness, bimodal, and bilateral implanted cochlear implant patients.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Article
- Frequency-to-Place Mismatch and Cochlear Implant Outcomes by Electrode Type.JAMA otolaryngology-- head & neck surgery · 2025Article
- Using musical pitch interval comparisons to assess cochlear implant frequency-to-place maps.Frontiers in audiology and otology · 2025Article
- Simulated auditory nerve response evoked by lateral-wall and peri-modiolar electrode arrays inserted in scala tympani or scala vestibuli.Frontiers in neuroscience · 2025Article
- Pediatric cochlear implantation: The impact of frequency-to-place mismatch after a three-year follow-up.PloS one · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
objectivesThe spatial position of a cochlear implant (CI) electrode array affects the spectral cues provided to the recipient. Differences in cochlear size and array length lead to substantial variability in angular insertion depth (AID) across and within array types. For CI-alone users, the variability in AID results in varying degrees of frequency-to-place mismatch between the default electric frequency filters and cochlear place of stimulation. For electric-acoustic stimulation (EAS) users, default electric frequency filters also vary as a function of residual acoustic hearing in the implanted ear. The present study aimed to (1) investigate variability in AID associated with lateral wall arrays, (2) determine the subsequent frequency-to-place mismatch for CI-alone and EAS users mapped with default frequency filters, and (3) examine the relationship between early speech perception for CI-alone users and two aspects of electrode position: frequency-to-place mismatch and angular separation between neighboring contacts, a metric associated with spectral selectivity at the periphery.
designOne hundred one adult CI recipients (111 ears) with MED-EL Flex24 (24 mm), Flex28 (28 mm), and FlexSOFT/Standard (31.5 mm) arrays underwent postoperative computed tomography to determine AID. A subsequent comparison was made between AID, predicted spiral ganglion place frequencies, and the default frequency filters for CI-alone (n = 84) and EAS users (n = 27). For CI-alone users with complete insertions who listened with maps fit with the default frequency filters (n = 48), frequency-to-place mismatch was quantified at 1500 Hz and angular separation between neighboring contacts was determined for electrodes in the 1 to 2 kHz region. Multiple linear regression was used to examine how frequency-to-place mismatch and angular separation of contacts influence consonant-nucleus-consonant (CNC) scores through 6 months postactivation.
resultsFor CI recipients with complete insertions (n = 106, 95.5%), the AID (mean ± standard deviation) of the most apical contact was 428° ± 34.3° for Flex24 (n = 11), 558° ± 65.4° for Flex28 (n = 48), and 636° ± 42.9° for FlexSOFT/Standard (n = 47) arrays. For CI-alone users, default frequency filters aligned closely with the spiral ganglion map for deeply inserted lateral wall arrays. For EAS users, default frequency filters produced a range of mismatches; absolute deviations of ≤ 6 semitones occurred in only 37% of cases. Participants with shallow insertions and minimal or no residual hearing experienced the greatest mismatch. For CI-alone users, both smaller frequency-to-place mismatch and greater angular separation between contacts were associated with better CNC scores during the initial 6 months of device use.
conclusionsThere is significant variability in frequency-to-place mismatch among CI-alone and EAS users with default frequency filters, even between individuals implanted with the same array. When using default frequency filters, mismatch can be minimized with longer lateral wall arrays and insertion depths that meet the edge frequency associated with residual hearing for CI-alone and EAS users, respectively. Smaller degrees of frequency-to-place mismatch and decreased peripheral masking due to more widely spaced contacts may independently support better speech perception with longer lateral wall arrays in CI-alone users.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.