ArticleAIDS (London, England)2020
Near point-of-care, point-mutation test to detect drug resistance in HIV-1: a validation study in a Mexican cohort.
Article in AIDS (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 17 citations in OpenAlex.
- "I feel drug resistance testing allowed us to make an informed decision": qualitative insights on the role of HIV drug resistance mutation testing among children and pregnant women living with HIV in western Kenya.BMC health services research · 2023Trial
- Simpler and faster Covid-19 testing: Strategies to streamline SARS-CoV-2 molecular assays.EBioMedicine · 2021Trial
- Oligonucleotide Ligation Assay (OLA)-Simple: Field Implementation, Usability, and Performance of a near Point-of-Care HIV Drug Resistance Assay in Kenya.Laboratories · 2026Article
- Development and Optimization of Oligonucleotide Ligation Assay (OLA) Probes for Detection of HIV-1 Resistance to Dolutegravir.Viruses · 2024Article
- Optimising HIV drug resistance testing laboratory networks in Kenya: insights from systems engineering modelling.BMJ open · 2024Article
- Advancing HIV Drug Resistance Technologies and Strategies: Insights from South Africa's Experience and Future Directions for Resource-Limited Settings.Diagnostics (Basel, Switzerland) · 2023Review
- Need assessment for HIV drug resistance testing and landscape of current and future technologies in low- and middle-income countries.PLOS global public health · 2023Review
- Simultaneous monitoring of HIV viral load and screening of SARS-CoV-2 employing a low-cost RT-qPCR test workflow.The Analyst · 2022Article
- Point-of-Care Tests for HIV Drug Resistance Monitoring: Advances and Potentials.Pathogens (Basel, Switzerland) · 2022Article
- Aptamer Sandwich Lateral Flow Assay (AptaFlow) for Antibody-Free SARS-CoV-2 Detection.Analytical chemistry · 2022Article
- Implementation of an interactive mobile application to pilot a rapid assay to detect HIV drug resistance mutations in Kenya.PLOS global public health · 2022Article
- Harmony COVID-19: A ready-to-use kit, low-cost detector, and smartphone app for point-of-care SARS-CoV-2 RNA detection.Science advances · 2021Article
- Rapid Near Point-of-Care Assay forAIDS research and human retroviruses · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 2 institutions in 1 country.
Funding
Abstract
objectivePretreatment HIV-drug resistance (PDR, HIVDR) to non-nucleoside reverse transcriptase inhibitors (NNRTIs) is increasing globally. NNRTIs continue to be used as first-line antiretroviral therapy (ART) in some communities due to the cost of dolutegravir-based ART or dolutegravir-associated adverse events. A simplified version of the oligonucleotide ligation assay (OLA) - 'OLA-Simple' - is a low-cost, near point-of-care assay that provides ready-to-use lyophilized reagents and reports HIVDR mutations as colored lines on lateral flow strips. Our objective was to design and validate OLA-Simple for a Mexican cohort.
designOLA-Simple probes to detect K65R, K103N/S, Y181C, M184V, and G190A were optimized for HIV Mexican sequences. Sixty clinical plasma specimens were analyzed by OLA-Simple by technicians blinded to Illumina-MiSeq sequences, and HIVDR results were compared.
methodsPlasma RNA was tested using OLA-Simple kits. OLA-Simple lateral flow strips were read by in-house software, and were classified as mutant or wild-type at each codon. The comparison of results by OLA-Simple and Miseq was used to generate receiver-operating characteristic curves.
resultsOLA-Simple PCR amplified 59 of 60 specimens and successfully genotyped 287 of 295 codons, with eight of 295 (2.7%) indeterminate results. Compared to MiSeq, OLA-Simple gave five of 295 (1.7%) false-positive and four of 295 (1.4%) false-negative results. Excluding indeterminate results, OLA-Simple classified mutant with an accuracy of 97.4 and 98.8% when using thresholds at 10 and 25% mutant within an individual's HIV quasispecies, respectively.
conclusionsCompared to MiSeq, OLA-Simple detected HIVDR with high sensitivity and accuracy. OLA-Simple could expand access to affordable and rapid HIVDR testing to guide appropriate ART choices in populations using NNRTI-based ART.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.