ArticleJournal of chemical information and modeling2020
Could Egg White Lysozyme be Solved by Single Particle Cryo-EM?
Article in Journal of chemical information and modeling, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Laser phase plate improves structure determination of small proteins by cryo-EM.Science (New York, N.Y.) · 2026Article
- Crossed laser phase plates for transmission electron microscopy.Nature communications · 2026Article
- Direct Measurement of Protein Pair Interaction Potential.ACS nano · 2026Article
- Article
- Extended Sampling of Macromolecular Conformations from Uniformly Distributed Points on Multidimensional Normal Mode Hyperspheres.Journal of chemical theory and computation · 2024Article
- Computational models of amorphous ice for accurate simulation of cryo-EM images of biological samples.Ultramicroscopy · 2024Article
- Evolving Experimental Techniques for Structure-Based Drug Design.The journal of physical chemistry. B · 2022Review
- Article
- Conquer by cryo-EM without physically dividing.Biochemical Society transactions · 2021Review
- Parakeet: a digital twin software pipeline to assess the impact of experimental parameters on tomographic reconstructions for cryo-electron tomography.Open biology · 2021Article
- Single-particle cryo-EM: alternative schemes to improve dose efficiency.Journal of synchrotron radiation · 2021Article
- Mycobacterium tuberculosis ferritin: a suitable workhorse protein for cryo-EM development.Acta crystallographica. Section D, Structural biology · 2021Article
- Priming mycobacterial ESX-secreted protein B to form a channel-like structure.Current research in structural biology · 2021Article
- Faces of Contemporary CryoEM Information and Modeling.Journal of chemical information and modeling · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The combination of high-end cryogenic transmission electron microscopes (cryo-EM), direct electron detectors, and advanced image algorithms allows researchers to obtain the 3D structures of much smaller macromolecules than years ago. However, there are still major challenges for the single-particle cryo-EM method to achieve routine structure determinations for macromolecules much smaller than 100 kDa, which are the majority of all plant and animal proteins. These challenges include sample characteristics such as sample heterogeneity, beam damage, ice layer thickness, stability, and quality, as well as hardware limitations such as detector performance, beam, and phase plate quality. Here, single particle data sets were simulated for samples that were ideal in terms of homogeneity, distribution, and stability, but with realistic parameters for ice layer, dose, detector performance, and beam characteristics. Reference data were calculated for human apo-ferritin using identical parameters reported for an experimental data set downloaded from EMPIAR. Processing of the simulated data set resulted in a value of 1.86 Å from 20 214 particles, similar to a 2 Å density map obtained from 29 224 particles selected from real micrographs. Simulated data sets were then generated for a 14 kDa protein, hen egg white lysozyme (HEWL), with and without an ideal phase plate (PP). Whereas we could not obtain a high-resolution 3D reconstruction of HEWL for the data set without PP, the one with PP resulted in a 2.78 Å resolution density map from 225 751 particles. Our simulator and simulations could help in pushing the size limits of cryo-EM.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.