ArticleInternational journal of laboratory hematology2020
Real-world assay variability between laboratories in monitoring of recombinant factor IX Fc fusion protein activity in plasma samples.
Article in International journal of laboratory hematology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 7 citations in OpenAlex.
- Global Comparative Antithrombin Field Study: Impact of Laboratory Assay Variability on the Assessment of Antithrombin Activity Measurement at Fitusiran Clinical Decision-Making Points.Haemophilia : the official journal of the World Federation of Hemophilia · 2025Article
- Recombinant factor IX Fc for major surgery in hemophilia B: factor IX plasma activity levels and effective hemostasis.Research and practice in thrombosis and haemostasis · 2023Article
- An Update on Laboratory Diagnostics in Haemophilia A and B.Hamostaseologie · 2022Review
- Managing surgery in hemophilia with recombinant factor VIII Fc and factor IX Fc: Data on safety and effectiveness from phase 3 pivotal studies.Research and practice in thrombosis and haemostasis · 2022Article
- Real-world assay variability between laboratories in monitoring of recombinant factor IX Fc fusion protein activity in plasma samples.International journal of laboratory hematology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 3 countries.
Funding
Abstract
introductionMonitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for one-stage clotting (OSC) assays. This study aimed to evaluate the real-world, interlaboratory variability of routine FIX activity assays used in clinical haemostasis laboratories for the measurement of recombinant FIX Fc fusion protein (rFIXFc) activity.
methodsHuman FIX-depleted plasma was spiked with rFIXFc at 0.80, 0.20 or 0.05 IU/mL based on label potency. Participating laboratories tested samples using their own routine OSC or chromogenic substrate (CS) assay protocols, reagents and FIX plasma standards. Laboratories could perform more than one measurement and method, and were not fully blinded to nominal activity values.
resultsA total of 142 laboratories contributed OSC results from 175 sample kits using 11 different activated partial thromboplastin time (aPTT) reagents. The median recovered FIX activity for the 0.80, 0.20 and 0.05 IU/mL samples was 0.72 IU/mL, 0.21 IU/mL and 0.060 IU/mL, respectively. Across all OSC reagents, interlaboratory variability (% CV) per aPTT reagent ranged from 9.4% to 32.1%, 8.2% to 32.6% and 12.2% to 42.0% at the 0.80, 0.20 and 0.05 IU/mL levels, respectively. CS results showed excellent median recoveries at all nominal levels (87.5% to 115.0%; n = 11) with low interlaboratory variability (CV 3.6% to 15.4%).
conclusionThis large, real-world data set indicates that rFIXFc activity in plasma samples can be accurately measured with the majority of routine OSC and CS assay methods. Given the variation in FIX assay procedures between sites, it is important that individual laboratories qualify their in-house methods for monitoring of rFIXFc activity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.