Evidence map›Paper›PMID 32199456›Full record

ArticleBMC cardiovascular disorders2020

Influence of microcirculation load on FFR in coronary artery stenosis model.

Hongzeng Xu, Jing Liu, Donghui Zhou, Yuanzhe Jin

Open access · goldAbstract read
In one paragraph

Article in BMC cardiovascular disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Hongzeng XuDepartment of Cardiology, The fourth Affiliated Hospital of China Medical University, No. 4, Chongshan Road, Huanggu District, Shenyang, 110032, China.
Jing LiuDepartment of Cardiology, The fourth Affiliated Hospital of China Medical University, No. 4, Chongshan Road, Huanggu District, Shenyang, 110032, China.
Donghui ZhouDepartment of Cardiology, The fourth Affiliated Hospital of China Medical University, No. 4, Chongshan Road, Huanggu District, Shenyang, 110032, China.
Yuanzhe JinDepartment of Cardiology, The fourth Affiliated Hospital of China Medical University, No. 4, Chongshan Road, Huanggu District, Shenyang, 110032, China. yzjin@cmu.edu.cn.
China Medical University · CNFourth Affiliated Hospital of China Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe coronary artery hemodynamics are impacted by both the macrocirculation and microcirculation. Whether microcirculation load impact the functional assessment of a coronary artery stenosis is unknown. The purpose of this study is to investigate the effect of porous media of the microcirculation on fractional flow reserve (FFR) in stenotic coronary artery model.

methodsA three dimensional computational simulation of blood flow in coronary artery symmetric stenotic model was constructed. The computational fluid dynamics (CFD) model was developed with Fluent 16.0. Blood was modeled as a shear thinning, non-Newtonian fluid with the Carreau model. A seepage outlet boundary condition and transient inlet conditions were imposed on the model. Coronary physiologica diagnostic parameter such as pressure, velocity and fractional flow reserve (FFR) were investigated in the model and compared with the microcirculation load (ML) and constant pressure load (PL) condition.

resultsThe present study showed the different hemodynamics in the ML and PL condition. The pre-stenotic pressure is almost the same in the two model. However the pressure in the post-stenotic artery domain is much lower in the PL model. The fluctuation range of the pressures is much higher in ML model than those in PL model. The velocity flow was more steady and lower in the ML model. For the PL model with 75% artery stenosis the FFR was 0.776, while for the ML model with the same stenosis, the FFR was 0.813.

conclusionsThis study provides evidence that FFR increased in the presentation of ML condition. There is a strong hemodynamic effect of microcirculation on coronary artery stenosis.

Indexed as

Computer SimulationFractional Flow Reserve, MyocardialHemodynamicsMicrocirculationModels, CardiovascularCoronary StenosisCoronary VesselsHumansCoronary artery diseaseFFRHemodynamicsMicrocirculation

Identifiers

PMID32199456
PMCPMC7085198
OpenAlexW3012427212

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.