ArticleSensors (Basel, Switzerland)2020
Progress on Range of Motion After Total Knee Replacement by Sensor-Based System.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 3 syntheses or guidelines pooled it, 42 citations in OpenAlex.
- Pooled it
- Telemedicine in orthopaedics and trauma surgery during the first year of COVID pandemic: a systematic review.BMC musculoskeletal disorders · 2023Pooled it
- A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation.Sensors (Basel, Switzerland) · 2021Pooled it
- A Novel Fabric Strain Sensor Array with Hybrid Deep Learning for Accurate Knee Movement Recognition.Micromachines · 2025Article
- Sensor Technologies and Rehabilitation Strategies in Total Knee Arthroplasty: Current Landscape and Future Directions.Sensors (Basel, Switzerland) · 2025Review
- A Sensor-Based Classification for Neuromotor Robot-Assisted Rehabilitation.Bioengineering (Basel, Switzerland) · 2025Review
- Research trends and frontiers in rehabilitation after total knee arthroplasty: based on bibliometric and visualization analysis.Journal of orthopaedic surgery and research · 2024Article
- A home-based tele-rehabilitation exercise system for patients after knee replacement surgery.BMC musculoskeletal disorders · 2024Article
- Three-Dimensional Human Posture Recognition by Extremity Angle Estimation with Minimal IMU Sensor.Sensors (Basel, Switzerland) · 2024Article
- Mobile and Computer-Based Applications for Rehabilitation Monitoring and Self-Management After Knee Arthroplasty: Scoping Review.JMIR mHealth and uHealth · 2024Article
- Sensor-Based Wearable Systems for Monitoring Human Motion and Posture: A Review.Sensors (Basel, Switzerland) · 2023Review
- Assessment of human gait after total knee arthroplasty by dynamic time warping algorithm.Healthcare technology letters · 2023Article
- A Portable Wearable Inertial System for Rehabilitation Monitoring and Evaluation of Patients With Total Knee Replacement.Frontiers in neurorobotics · 2022Article
- Design of an FPGA-Based Fuzzy Feedback Controller for Closed-Loop FES in Knee Joint Model.Micromachines · 2021Article
- Using Artificial Intelligence for Pattern Recognition in a Sports Context.Sensors (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
For total knee replacement (TKR) patients, rehabilitation after the surgery is key toregaining mobility. This study proposes a sensor-based system for effectively monitoringrehabilitation progress after TKR. The system comprises a hardware module consisting of thetriaxial accelerometer and gyroscope, a microcontroller, and a Bluetooth module, and a softwareapp for monitoring the motion of the knee joint. Three indices, namely the number of swings, themaximum knee flexion angle, and the duration of practice each time, were used as metrics tomeasure the knee rehabilitation progress. The proposed sensor device has advantages such asusability without spatiotemporal constraints and accuracy in monitoring the rehabilitation progress.The performance of the proposed system was compared with the measured range of motion of theCybex isokinetic dynamometer (or Cybex) professional rehabilitation equipment, and the resultsrevealed that the average absolute errors of the measured angles were between 1.65° and 3.27° forthe TKR subjects, depending on the swing speed. Experimental results verified that the proposedsystem is effective and comparable with the professional equipment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.