ArticleJournal of applied clinical medical physics2020
Use of surface-guided radiation therapy in combination with IGRT for setup and intrafraction motion monitoring during stereotactic body radiation therapy treatments of the lung and abdomen.
Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
34 citing papers in PubMed.
- Enhancing inter-fraction set-up accuracy and margin minimization (E-SAMM): a comparison of maskless surface-guided and mask-based laser alignment positioning in pelvic radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026Article
- Feasibility of surface-guided radiotherapy for detecting patient instability during prostate radiotherapy.Radiation oncology journal · 2026Article
- Quantifying upright positioning accuracy with optical surface tracking in radiotherapy.Journal of applied clinical medical physics · 2026Article
- Implementation of an FMEA-guided quality-improvement workflow is associated with improved setup accuracy in lung stereotactic body radiotherapy.Frontiers in oncology · 2026Article
- Application of respiratory motion management technology for patients with lung cancer treated with stereotactic body radiotherapy (Review).Oncology letters · 2025Review
- Modern Approaches for Thoracic Image Registration and Respiratory Motion Management in Oncology.Radiology. Imaging cancer · 2025Review
- Translating SGRT from Breast to Lung Cancer: A Study on Frameless Immobilization and Real-Time Monitoring Efficacy, Focusing on Setup Accuracy.Life (Basel, Switzerland) · 2025Article
- A novel SGRT system for real-time optical surface tracking or guidance.Journal of applied clinical medical physics · 2025Article
- Development of dedicated phantom for end-to-end testing of multiple image-guidance configurations incorporating light-section-based surface guidance system.Journal of applied clinical medical physics · 2025Article
- Recent Advances and Current Challenges in Stereotactic Body Radiotherapy for Ultra-Central Lung Tumors.Cancers · 2024Review
- New findings on clinical experience on surface-guided radiotherapy for frameless non-coplanar stereotactic radiosurgery treatments.Journal of applied clinical medical physics · 2024Article
- Article
- Surface guided radiotherapy practice in paediatric oncology: a survey on behalf of the SIOPE Radiation Oncology Working Group.The British journal of radiology · 2024Article
- Role of Metastasis-Directed Therapy in Genitourinary Cancers.Current treatment options in oncology · 2024Review
- SGRT-based stereotactic body radiotherapy for lung cancer setup accuracy and margin of the PTV.Journal of applied clinical medical physics · 2024Article
- Automated Test for Monthly Quality Assurance of Optical Surface Imaging Dynamic Localization Accuracy.Cureus · 2024Article
- Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2024Article
- Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system.Radiological physics and technology · 2023Article
- Surface-Guided Radiotherapy: Can We Move on from the Era of Three-Point Markers to the New Era of Thousands of Points?Bioengineering (Basel, Switzerland) · 2023Review
- Setup accuracy and margins for surface-guided radiotherapy (SGRT) of head, thorax, abdomen, and pelvic target volumes.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeMultiple techniques can be used to assist with more accurate patient setup and monitoring during Stereotactic body radiation therapy (SBRT) treatment. This study analyzes the accuracy of 3D surface mapping with Surface-guided radiation therapy (SGRT) in detecting interfraction setup error and intrafraction motion during SBRT treatments of the lung and abdomen. MATERIALS AND
methodsSeventy-one patients with 85 malignant thoracic or abdominal tumors treated with SBRT were analyzed. For initial patient setup, an alternating scheme of kV/kV imaging or SGRT was followed by cone beam computed tomography (CBCT) for more accurate tumor volumetric localization. The CBCT six degree shifts after initial setup with each method were recorded to assess interfraction setup error. Patients were then monitored continuously with SGRT during treatment. If an intrafractional shift in any direction >2 mm for longer than 2 sec was detected by SGRT, then CBCT was repeated and the recorded deltas were compared to those detected by SGRT.
resultsInterfractional shifts after SGRT setup and CBCT were small in all directions with mean values of <5 mm and < 0.5 degrees in all directions. Additionally, 25 patients had detected intrafraction motion by SGRT during a total of 34 fractions. This resulted in 25 (73.5%) additional shifts of at least 2 mm on subsequent CBCT. When comparing the average vector detected shift by SGRT to the resulting vector shift on subsequent CBCT, no significant difference was found between the two.
conclusionsSurface-guided radiation therapy provides initial setup within 5 mm for patients treated with SBRT and can be used in place of skin marks or planar kV imaging prior to CBCT. In addition, continuous monitoring with SGRT during treatment was valuable in detecting potentially clinically meaningful intrafraction motion and was comparable in magnitude to shifts from additional CBCT scans. PTV margin reduction may be feasible for SBRT in the lung and abdomen when using SGRT for continuous patient monitoring during treatment.