ArticleInternational ophthalmology2020

Effect of corneal marking features on toric intraocular lens alignment.

Hasan Aytogan

Abstract read
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Hasan AytoganT.C.S.B.U. Tepecik Eğitim Ve Araştırma Hastanesi, Güney mahallesi 1140/1.sok no. 1, 35180, Yenişehir, Konak, Izmir, Turkey. Hasan_aytogan@hotmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to investigate the relation of the corneal ink mark size, shape, and location with the corneal perimeter in terms of the corresponding corneal axis. MATERIAL AND

methodsThis study was designed both prospective experimental and literature search. Contact lenses were used to demonstrate the spreading effect of the surgical ink mark. Open-access published corneal images with corneal ink marks were reviewed. Mark size and perimeter of both contact lenses and corneal images were performed in Image J software.

resultsTwenty contact lenses and 15 corneal images with 32 corneal marks, which were obtained from the literature, were included in the study. Mean degree corresponding to the ink size for the group 1 was 8.3° ± 1.2° (range 5.5-10.3), for group 2 was 11° ± 1.1° (range 8-12), for group 3 was 4.2° ± 0.7° (range 3.2-5.5), for group 4 was 4.2° ± 0.7° (range 3.2-5.5), and for group 5 was 6.3° ± 2.5° (range 2-11.5). DISCUSSION: Theoretically, it is wise to target further located ink mark from central cornea based on the 360/2π × (r2 - r1)/(r1 × r2) × M formula. It has been experimentally shown that the smaller corneal perimeter and closer mark to the central cornea may lead the more significant deviation from the targeted axis. Preoperative manual corneal marking may be more responsible for residual astigmatism than it is thought.

Indexed as

AstigmatismCorneaLenses, IntraocularPhacoemulsificationHumansLens Implantation, IntraocularProspective StudiesRefraction, OcularAstigmatismManual corneal markingResidual astigmatismToric IOL