Evidence map›Paper›PMID 32193468›Full record

ArticleScientific reports2020

Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance.

Jannike Nickander, Magnus Lundin, Goran Abdula, Jonas Jenner, Eva Maret, Peder Sörensson, Einar Heiberg, Andreas Sigfridsson, Martin Ugander

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Automatic failure mode evaluation using non-linear phase contrast correction to improve flow measurement accuracy in cardiovascular magnetic resonance phase contrast imaging.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Jannike NickanderDepartment of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
Magnus LundinDepartment of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
Goran AbdulaDepartment of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
Jonas JennerDepartment of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
Eva MaretDepartment of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
Peder SörenssonDepartment of Medicine, Unit of Cardiology, Karolinska Institutet, and Karolinska University Hospital, Stockholm, Sweden.
Einar HeibergDepartment of Clinical Physiology, Lund University, and Skåne University Hospital, Lund, Sweden.
Andreas SigfridssonDepartment of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
Martin UganderDepartment of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden. martin.ugander@gmail.com.
Karolinska Institutet · SEKarolinska University Hospital · SERoyal North Shore Hospital · AUSkåne University Hospital · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patients (n = 10) with verified cardiac shunts in this retrospective study. All patients underwent phase contrast flow quantification in the ascending aorta and pulmonary trunk. Flow was quantified using two semi-automatic software platforms (SyngoVia VA30, Vendor 1; Segment 2.0R4534, Vendor 2). Measurements were performed both uncorrected and corrected for linear (Vendor 1 and Vendor 2) or quadratic (Vendor 2) background phase. The proportion of patients outside the normal range of Qp/Qs was compared using the McNemar's test. Compared to uncorrected measurements, there were fewer patients with a Qp/Qs outside the normal range following linear correction using Vendor 1 (10% vs 18%, p < 0.001), and Vendor 2 (10% vs 18%, p < 0.001), and following quadratic correction using Vendor 2 (7% vs 18%, p < 0.001). No patient with known shunt was reclassified as normal following stationary background correction. Therefore, we conclude that stationary tissue background correction reduces the number of patients with a Qp/Qs ratio outside the normal range in a consecutive clinical population, while simultaneously not reclassifying any patient with known cardiac shunts as having a normal Qp/Qs. Stationary tissue background correction may be used in clinical patients to increase diagnostic precision.

Indexed as

Blood Flow VelocityPulmonary CirculationAdultAortaCardiovascular DiseasesFemaleHumansMagnetic Resonance ImagingMaleMiddle AgedPulmonary ArteryRetrospective StudiesSensitivity and Specificity

Identifiers

PMID32193468
PMCPMC7081189
OpenAlexW3011896485

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked