ArticleClinical orthopaedics and related research2020
Synovial Fluid Aspirates Diluted with Saline or Blood Reduce the Sensitivity of Traditional and Contemporary Synovial Fluid Biomarkers.
Article in Clinical orthopaedics and related research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 1 synthesis or guideline pooled it, 41 citations in OpenAlex.
- The role of biopsy in diagnosing infection after hip and knee arthroplasty: a meta-analysis.Archives of orthopaedic and trauma surgery · 2023Pooled it
- Article
- Value of "true" leukocytosis formula in determining total knee arthroplasty prosthetic joint infection in the community hospital setting.World journal of orthopedics · 2026Article
- Systematic evaluation of pre-analytical variables on synovial fluid metabolomic profiles using GC-ToF-MS and UHPLC-MS.The Analyst · 2026Article
- Interlaboratory Reliability of Synovial Fluid Analysis in Prosthetic Knee Aspiration.Arthroplasty today · 2026Article
- Improved detection of Mycobacterium tuberculosis in lymph node aspirates through GeneXpert MTB/RIF assay in Bangladesh.BMC infectious diseases · 2026Article
- Article
- Article
- Preoperative Synovial Fluid Cultures, and Biopsy Cultures After Dry Tap Aspiration, Are Valuable in Diagnosing a Periprosthetic Joint Infection: A Retrospective Study.Microorganisms · 2025Article
- Synovial fluid dual-biomarker algorithm accurately differentiates osteoarthritis from inflammatory arthritis.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025Article
- Novel Method for Routine Ultrasound-Guided Serum Collection for Biomarker Analysis Around the Knee Joint.F1000Research · 2025Article
- Noncontact Diffuse Reflectance Spectroscopy of Synovial Fluid Samples for Rapid Identification of Infections.Journal of biophotonics · 2024Article
- Imaging approach to prosthetic joint infection.Skeletal radiology · 2024Review
- Diagnostics in Late Periprosthetic Infections-Challenges and Solutions.Antibiotics (Basel, Switzerland) · 2024Review
- The diagnosis and treatment of septic hip with osteonecrosis of the femoral head.Journal of orthopaedic surgery and research · 2024Article
- Pre-aspiration outpatient ultrasound can accurately predict dry taps in prosthetic hips suspected of infection; a prospective study.Frontiers in surgery · 2024Article
- Synovial Fluid C-reactive Protein Clinical Decision Limit and Diagnostic Accuracy for Periprosthetic Joint Infection.Cureus · 2024Article
- Joint aspiration for diagnosis of chronic periprosthetic joint infection: when, how, and what tests?Arthroplasty (London, England) · 2023Review
- Mitigating Concerns Over Transport Delays: An Analysis of Synovial Fluid Culture Results in Arthroplasty.Cureus · 2023Article
- Factors predicting hip joint aspiration yield or "dry taps" in patients with total hip arthroplasty.Journal of orthopaedic surgery and research · 2022Article
Corrections and comments
- Commented on by
Authors and funding
4 authors at 1 institution in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRecent criteria-based diagnostic tools to diagnose periprosthetic infection (PJI), such as the International Consensus Meeting (ICM) definition of PJI, are heavily reliant on synovial fluid laboratory results. Despite the importance of synovial fluid in PJI diagnosis, the effect of the quality of synovial fluid aspirate on testing results has not been studied. Our laboratory has established quality control parameters to identify synovial fluid aspirates that are highly diluted by saline or blood, which appear to degrade the diagnostic performance of synovial fluid laboratory tests. QUESTIONS/PURPOSES: (1) What proportion of synovial fluid aspirates analyzed at one laboratory are of poor quality (defined as having a red blood count > 1M cells/uL or an optical density at 280 nm < 0.324 or > 1.19)? (2) Does a poor-quality aspirate decrease the sensitivities of International Consensus Meeting-based scores and other synovial fluid biomarker tests in terms of their ability to anticipate a positive culture?
methodsFrom January 2016 to July 2019, a total of 123,549 synovial fluid samples were submitted to one laboratory for the purpose of diagnostic testing. Of these, 14% (16,773 of 123,549) samples were excluded because they were from a site other than a hip, knee, or shoulder arthroplasty, and an additional 33% (35,660 of 106,776) were excluded due to insufficient requested tests, resulting in 58% (71,116 of 123,549) samples included in this study. Specimens diluted with extreme levels of saline or blood were identified (defined as having a red blood count >1 M cells/uL or an optical density at 280 nm < 0.324 or > 1.19) as poor-quality aspirates. The sensitivities of synovial fluid C-reactive protein, alpha defensin, neutrophil elastase, white blood cell count, polymorphonuclear cell percentage, and the 2018 ICM-based tool were assessed in good-quality versus poor-quality synovial fluid samples. To avoid bias from using these evaluated tests within the reference definition of PJI in this study, a positive culture resulting from the synovial fluid served as the reference diagnosis defining a control cohort of PJI-positive samples. Although the low false-positive rate of synovial fluid culture allows for the valid estimation of synovial fluid test sensitivity, the high false-negative rate of synovial fluid culture prevents the valid estimation of test specificity, which was not evaluated in this study.
resultsOf the samples analyzed, 8% (6025 of 71,116) were found to have poor quality, in that they were substantially compromised by saline and/or blood. The sensitivity of all tests to detect culture-positive synovial fluid was lower in poor-quality than in good-quality samples: 2018 International Consensus Meeting-based tool (83% [95% CI 80 to 86] versus 97% [95% CI 96 to 97]), synovial fluid C-reactive protein (65% [95% CI 61 to 69] versus 88% [95% CI 87 to 89]), alpha defensin (70% [95% CI 66 to 73] versus 93% [95% CI 93 to 94]), neutrophil elastase (80% [95% CI 77 to 83] versus 96% [95% CI 96 to 97]), synovial fluid white blood cell count (69% [95% CI 65 to 73] versus 93% [95% CI 93 to 94]), and the polymorphonuclear cell percentage (88% [95% CI 85 to 91] versus 95% [95% CI 94 to 95]), with all p < 0.001.
conclusionsWhen synovial fluid is substantially diluted with saline or blood, the biomarkers and cells being measured are also diluted, decreasing the sensitivity of laboratory testing. We recommend that future diagnostic studies exclude these samples because an artificial reduction in test sensitivity will be observed. CLINICAL RELEVANCE: Clinicians should avoid relying on negative synovial fluid testing to rule out PJI when the fluid submitted is substantially constituted of saline or blood. Further studies are necessary to understand the diagnostic utility, if any, of these diluted aspirate samples.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.