Evidence map›Paper›PMID 32190569›Full record

ArticleQuantitative imaging in medicine and surgery2020

Volumetric cine magnetic resonance imaging (VC-MRI) using motion modeling, free-form deformation and multi-slice undersampled 2D cine MRI reconstructed with spatio-temporal low-rank decomposition.

Wendy Harris, Fang-Fang Yin, Jing Cai, Lei Ren

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Motion modeling from 4D MR images of liver simulating phantom.Journal of applied clinical medical physics · 2022
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wendy HarrisMedical Physics Graduate Program, Duke University, Durham, NC, USA.
Fang-Fang YinMedical Physics Graduate Program, Duke University, Durham, NC, USA.
Jing CaiMedical Physics Graduate Program, Duke University, Durham, NC, USA.
Lei RenMedical Physics Graduate Program, Duke University, Durham, NC, USA.

Funding

Hybrid virtual-MRI/CBCT: A new paradigm for image guidance in liver SBRTR01EB028324 · NIBIB · UNIVERSITY OF MARYLAND BALTIMORE · PI REN, LEI, YIN, FANG-FANG · 2019 to 2022
$2.1M
A Limited-angle Intra-fractional Verification (LIVE) System for SBRT TreatmentsR01CA184173 · NCI · DUKE UNIVERSITY · PI REN, LEI, YIN, FANG-FANG · 2015 to 2018
$1.5M
NCI NIH HHS R01 CA184173NIBIB NIH HHS R01 EB028324
6 · The paper itself

Abstract

backgroundThe purpose of this study is to improve on-board volumetric cine magnetic resonance imaging (VC-MRI) using multi-slice undersampled cine images reconstructed using spatio-temporal k-space data, patient prior 4D-MRI, motion modeling (MM) and free-form deformation (FD) for real-time 3D target verification of liver and lung radiotherapy.

methodsA previous method was developed to generate on-board VC-MRI by deforming prior MRI images based on a MM and a single-slice on-board 2D-cine image. The two major improvements over the previous method are: (I) FD was introduced to estimate VC-MRI to correct for inaccuracies in the MM; (II) multi-slice undersampled 2D-cine images reconstructed by a k-t SLR reconstruction method were used for FD-based estimation to maintain the temporal resolution while improving the accuracy of VC-MRI. The method was evaluated using XCAT lung simulation and four liver patients' data.

resultsFor XCAT, VC-MRI estimated using ten undersampled sagittal 2D-cine MRIs resulted in volume percent difference/volume dice coefficient/center-of-mass shift of 9.77%±3.71%/0.95±0.02/0.75±0.26 mm among all scenarios based on estimation with MM and FD. Adding FD optimization improved VC-MRI accuracy substantially for scenarios with anatomical changes. For patient data, the mean tumor tracking errors were 0.64±0.51, 0.62±0.47 and 0.24±0.24 mm along the superior-inferior (SI), anterior-posterior (AP) and lateral directions, respectively, across all liver patients.

conclusionsIt is feasible to improve VC-MRI accuracy while maintaining high temporal resolution using FD and multi-slice undersampled 2D cine images for real-time 3D target verification.

Indexed as

free-form deformationk-t SLR reconstructionmotion modelingtarget verificationVolumetric-cine magnetic resonance imaging (volumetric-cine MRI)

Identifiers

PMID32190569
PMCPMC7063294

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked