Evidence map›Paper›PMID 32189945›Full record

ArticleJournal of clinical orthopaedics and trauma2020

Does increased femoral component size options reduce anterior femoral notching in total knee replacement?

Anshu Shekhar, Ch Chandra Krishna, Shantanu Patil, Sachin Tapasvi

Abstract read
In one paragraph

Article in Journal of clinical orthopaedics and trauma, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. [Research progress of anterior femoral notching in total knee arthroplasty].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Anshu ShekharThe Orthopaedic Speciality Clinic, 16 Status Chambers, 1221/A Wrangler Paranjpe Road, Off F.C. Road, Pune, 411004, India.
Ch Chandra KrishnaThe Orthopaedic Speciality Clinic, 16 Status Chambers, 1221/A Wrangler Paranjpe Road, Off F.C. Road, Pune, 411004, India.
Shantanu PatilDepartment of Translational Medicine & Research, SRM Medical College and Hospitals, SRM Institute of Science & Technology, Kattankulathur, Tamil Nadu, 603203, India.
Sachin TapasviThe Orthopaedic Speciality Clinic, 16 Status Chambers, 1221/A Wrangler Paranjpe Road, Off F.C. Road, Pune, 411004, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTotal knee arthroplasty (TKA) is currently the best option for management of advanced knee arthritis for patients who have exhausted conservative management. There have been significant implant design improvements and this is a continuing process to help the surgeon replicate patient anatomy and kinematics. Amongst the many variables in implantation to achieve a well-functioning TKA, getting optimal femoral component sizing is one. Every implant system has certain discreet implant sizes and the surgeon has to strive to obtain the best fit possible for the patient and attain a well aligned and stable TKA. The aim of this study was to assess the frequency of various femoral component sizes being implanted with a system which has 2.5 mm antero-posterior increment between sizes, and to assess the incidence of anterior femoral notching when using a posterior referencing system. MATERIALS AND

methodsA retrospective analysis of 739 TKAs implanted in 532 patients between January 2013 and January 2016 at a single center using a single posterior stabilized implant system was done. Patient demographics and femur component size used was obtained from hospital patient records. Immediate post-operative radiographs were analyzed to look for anterior femoral notching and presence of this was classified according to Tayside classification. A telephonic follow up at minimum 2 tears post-surgery was done to interview for occurrence of supracondylar femur fracture or revision for any other causes.

resultsThere were 207 bilateral and 325 unilateral TKAs performed in 532 patients during the study period. There were 245 males and 287 females with an average age of 61.3 years (43-81 years, SD = 7.2). The most commonly used femoral component was 60 mm and an intermediate size prosthesis was used in 43.11% patients. The incidence of femoral notching ranged from 0 to 6.3%. No patient had sustained a supracondylar condylar fracture at minimum 2 years follow up.

conclusionThe availability of a larger number of femoral components in a TKA system allows the surgeon the modularity to choose and obtain the best fit possible. Restoration of posterior condylar offset, preventing anterior notching, medio-lateral overhang and patellofemoral joint stuffing are greatly dependent on correct femoral component sizing. The findings from our study underscore the need to use an implant system with as many femoral size options as possible with lesser increments in between sizes to minimize anterior femoral notching when using a posterior referencing technique.

Indexed as

ArthroplastyComponentFemurFittingKneeProsthesisReplacementTreatment outcome

Identifiers

PMID32189945
PMCPMC7068002

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked