ArticleProceedings of SPIE--the International Society for Optical Engineering2018
SLIC robust (SLICR) processing for fast, robust CT myocardial blood flow quantification.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- SLIC-Occ: functional segmentation of occupancy images improves precision of ECEJNMMI physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
There are several computational methods for estimating myocardial blood flow (MBF) using CT myocardial perfusion imaging (CT-MPI). Previous work has shown that model-based deconvolution methods are more accurate and precise than model-independent methods such as singular value decomposition and max-upslope. However, iterative optimization is computationally expensive and models are sensitive to image noise, thus limiting the utility of low x-ray dose acquisitions. We propose a new processing method, SLICR, which segments the myocardium into super-voxels using a modified simple linear iterative clustering (SLIC) algorithm and quantifies MBF via a robust physiologic model (RPM). We compared SLICR against voxel-wise SVD and voxel-wise model-based deconvolution methods (RPM, single-compartment and Johnson-Wilson). We used image data from a digital CT-MPI phantom to evaluate robustness of processing methods to noise at reduced x-ray dose. We validate SLICR in a porcine model with and without partial occlusion of the LAD coronary artery with known pressure-wire fractional flow reserve. SLICR was ~50 times faster than voxel-wise RPM and other model-based methods while retaining sufficient resolution to show all clinically interesting features (e.g., a flow deficit in the endocardial wall). SLICR showed much better precision and accuracy than the other methods. For example, at simulated MBF=100 mL/min/100g and 100 mAs exposure (50% of nominal dose) in the digital simulator, MBF estimates were 101 ± 12 mL/min/100g, 160 ± 54 mL/min/100g, and 122 ± 99 mL/min/100g for SLICR, SVD, and Johnson-Wilson, respectively. SLICR even gave excellent results (103 ± 23 ml/min/100g) at 50 mAs, corresponding to 25% nominal dose.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.