Evidence map›Paper›PMID 32185566›Full record

ArticleEJNMMI physics2020

Evaluation of a new multipurpose whole-body CzT-based camera: comparison with a dual-head Anger camera and first clinical images.

Cédric Desmonts, Mohammed Abdeldjalil Bouthiba, Blandine Enilorac, Catherine Nganoa, Denis Agostini, Nicolas Aide

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed
6.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 108 citations in OpenAlex.

  1. Head-to-head comparison ofEJNMMI research · 2026
    Article
  2. QuantitativeEJNMMI physics · 2026
    Article
  3. Article
  4. Article
  5. Quantitative SPECT/CT: Technique and Clinical Applications.Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer · 2026
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Review
  16. Bias and precision of SPECT-basedEJNMMI physics · 2024
    Article
  17. 360° CZT-SPECT/CT cameras:EJNMMI physics · 2024
    Article
  18. EANM perspectives for CZT SPECT in brain applications.European journal of nuclear medicine and molecular imaging · 2024
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Cédric DesmontsDepartment of Nuclear Medicine, Caen University Hospital, Avenue de la côte de Nacre, 14033, Caen Cedex 9, France. desmonts-c@chu-caen.fr.ORCID https://orcid.org/0000-0003-4963-4170
Mohammed Abdeldjalil BouthibaNormandie University, Caen, France.
Blandine EniloracDepartment of Nuclear Medicine, Caen University Hospital, Avenue de la côte de Nacre, 14033, Caen Cedex 9, France.
Catherine NganoaDepartment of Nuclear Medicine, Caen University Hospital, Avenue de la côte de Nacre, 14033, Caen Cedex 9, France.
Denis AgostiniDepartment of Nuclear Medicine, Caen University Hospital, Avenue de la côte de Nacre, 14033, Caen Cedex 9, France.
Nicolas AideDepartment of Nuclear Medicine, Caen University Hospital, Avenue de la côte de Nacre, 14033, Caen Cedex 9, France.
Normandie Université · FRUniversité de Caen Normandie · FRCentre Hospitalier Universitaire de Caen Normandie · FRInserm · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEvaluate the physical performance of the VERITON CzT camera (Spectrum Dynamics, Caesarea, Israel) that benefits from new detection architecture enabling whole-body imaging compared to that of a conventional dual-head Anger camera.

methodsDifferent line sources and phantom measurements were performed on each system to evaluate spatial resolution, sensitivity, energy resolution and image quality with acquisition and reconstruction parameters similar to those used in clinical routine. Extrinsic resolution was assessed using

resultsExtrinsic and tomographic resolution in the brain and body phantoms at the centre of the FOV was estimated at 3.55, 7.72 and 6.66 mm for the CzT system and 2.47, 7.75 and 7.72 mm for the conventional system, respectively. The energy resolution measured at 140 keV was 5.46% versus 9.21% for the Anger camera and was higher in a same manner for all energy peaks tested. Tomographic sensitivity for a point source in air was estimated at 236 counts·s

conclusionThe CzT camera has a superior sensitivity, higher energy resolution and better image contrast than the conventional SPECT camera, whereas spatial resolution remains similar. Introduction of this new technology may change current practices in nuclear medicine such as decreasing acquisition time and activity injected to patient.

Indexed as

Molecular imagingMultipurpose CzT-cameraSPECTWhole-body imaging

Identifiers

PMID32185566
PMCPMC7078403
OpenAlexW3010925341

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.