Can Tinted Lenses Be Used to Manipulate Pupil Size and Visual Performance When Wearing Multifocal Contact Lenses?

Hyung Min Park, Young Uk Ryu, Inn-Jee Park, Byoung Sun Chu

Open access · goldAbstract read
In one paragraph

Article in Clinical optometry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Hyung Min ParkSchool of Optometry and Vision Science, Daegu Catholic University, Gyeongsan-si, Republic of Korea.ORCID 0000-0003-1402-7274
Young Uk RyuDepartment of Physical Therapy, Daegu Catholic University, Gyeongsan-si, Republic of Korea.
Inn-Jee ParkSchool of Optometry and Vision Science, Daegu Catholic University, Gyeongsan-si, Republic of Korea.
Byoung Sun ChuSchool of Optometry and Vision Science, Daegu Catholic University, Gyeongsan-si, Republic of Korea.ORCID 0000-0001-9419-2194
Daegu Catholic University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purpose of this study is to investigate the effect of wearing neutral density (ND) filters with different transmittance levels over multifocal contact lenses (MTF CLs) on pupil size, visual functions and the dynamic accommodative response under daylight conditions in early presbyopes.

methodsSeventeen individuals aged between 40 and 48 years (mean age 42.35±2.62 years) were recruited to participate in this study. This study involved a repeated-measures design with two within-subject factors: optical condition (which had five levels), and fixation distance (which had three levels). The five optical conditions were no correction (baseline), MTF CL wear, MTF CL wear + 0.3 ND filter (transmission [Tv]=48.38%), MTF CL wear + 0.6 ND filter (Tv=27.12%) and MTF CL wear + 0.9 ND filter (Tv=14.58%). The three fixation distances were 3 m, 40 cm and 20 cm. Outcome measures were pupil size, the measured accommodative response (optical aid + physiological accommodation), distance visual acuity (VA), near VA and contrast sensitivity (CS).

resultsThere was no effect of optical condition on the accommodative response; however, there was a significant effect of fixation distance. (Accommodative response was 0.44±0.29, 1.83±0.37 and 4.03±0.46 D for fixation distances of 3 m, 40 cm and 20 cm, respectively; p<0.05.) There was a significant effect of optical condition (

conclusionThis study demonstrated that in a group of adults with early presbyopia, the use of ND filters enlarged pupil size. However, the combination of enlarged pupils and MTF CL did not improve distance vision, and if transmittance was reduced by 50% it resulted in decrements in vision and CS. MTF CL designs which incorporate tints, or tints that vary in darkness in response to ultraviolet exposure, should consider these findings.

Indexed as

accommodative responsesmultifocal contact lenspupil sizetinted lensvision

Identifiers

PMID32184694
PMCPMC7062197
OpenAlexW3009978279

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.