Evidence map›Paper›PMID 32183097›Full record

ArticleSensors (Basel, Switzerland)2020

Laser-based Thickness Control in a Double-Side Polishing System for Silicon Wafers.

Liang Zhu, Biao Mei, Weidong Zhu, Wei Li

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Liang ZhuSchool of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.
Biao MeiQuanzhou Institute of Equipment manufacturing, Haixi Institutes, Chinese Academy of Sciences, Quanzhou 362216, China.
Weidong ZhuSchool of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.
Wei LiSchool of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.
Zhejiang University · CNQuanzhou Institute of Equipment Manufacturing Haixi Institute · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Thickness control is a critical process of automated polishing of large and thin Si wafers in the semiconductor industry. In this paper, an elaborate double-side polishing (DSP) system is demonstrated, which has a polishing unit with feedback control of wafer thickness based on the scan data of a laser probe. Firstly, the mechanical structure, as well as the signal transmission and control of the DSP system, are discussed, in which the thickness feedback control is emphasized. Then, the precise positioning of the laser probe is explored to obtain the continuous and valid scan data of the wafer thickness. After that, a B-spline model is applied for the characterization of the wafer thickness function to provide the thickness control system with credible thickness deviation information. Finally, experiments of wafer-thickness evaluation and control are conducted on the presented DSP system. With the advisable number of control points in B-spline fitting, the thickness variation can be effectively controlled in wafer polishing with the DSP system, according to the experimental results of curve fitting and the statistical analysis of the experimental data.

Indexed as

B-spline fittingdouble-side polishing systemlaser probesilicon waferthickness control

Identifiers

PMID32183097
PMCPMC7147602
OpenAlexW3011574679

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials