ArticleJournal of applied clinical medical physics2020
A plan template-based automation solution using a commercial treatment planning system.
Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 7 citations in OpenAlex.
- A rule-based, feedback-driven framework for fully automated prostate VMAT planning.Journal of applied clinical medical physics · 2026Article
- OVH-guided planning for superior heart and lung sparing in breast cancer radiotherapy.Journal of applied clinical medical physics · 2026Article
- Validation of knowledge-based and multicriterial optimization assistive auto-planning algorithms for prostate VMAT radiotherapy using biological optimization.Journal of applied clinical medical physics · 2025Article
- NRG Oncology Assessment of Artificial Intelligence for Automatic Treatment Planning in Radiation Therapy Clinical Trials: Present and Future.International journal of radiation oncology, biology, physics · 2025Article
- Synthesizing Efficiency Tools in Radiotherapy to Increase Patient Flow: A Comprehensive Literature Review.Clinical Medicine Insights. Oncology · 2024Review
- Using Artificial Intelligence for Optimization of the Processes and Resource Utilization in Radiotherapy.JCO global oncology · 2022Review
- Automated Radiotherapy Planning for Head-and-neck Cancer: Multi-institutional Development, Validation, and Clinical Implementation of Monaco Scripting.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to develop an auto-planning platform to be interfaced with a commercial treatment planning system (TPS). The main goal was to obtain robust and high-quality plans for different anatomic sites and various dosimetric requirements.
methodsMonaco (Elekta, St. Louis, US) was the TPS in this work. All input parameters for inverse planning could be defined in a plan template inside Monaco. A software tool called Robot Framework was used to launch auto-planning trials with updated plan templates. The template modifier external to Monaco was the major component of our auto-planning platform. For current implementation, it was a rule-based system that mimics the trial-and-error process of an experienced planner. A template was automatically updated by changing the optimization constraints based on dosimetric evaluation of the plan obtained in the previous trial, along with the data of the iterative optimization extracted from Monaco. Treatment plans generated by Monaco with all plan evaluation criteria satisfied were considered acceptable, and such plans would be saved for further evaluation by clinicians. The auto-planning platform was validated for 10 prostate and 10 head-and-neck cases in comparison with clinical plans generated by experienced planners.
resultsThe performance and robustness of our auto-planning platform was tested with clinical cases of prostate and head and neck treatment. For prostate cases, automatically generated plans had very similar plan quality with the clinical plans, and the bladder volume receiving 62.5 Gy, 50 Gy, and 40 Gy in auto-plans was reduced by 1%, 3%, and 5%, respectively. For head and neck cases, auto-plans had better conformity with reduced dose to the normal structures but slightly higher dose inhomogeneity in the target volume. Remarkably, the maximum dose in the spinal cord and brain stem was reduced by more than 3.5 Gy in auto-plans. Fluence map optimization only with less than 30 trials was adequate to generate acceptable plans, and subsequent optimization for final plans was completed by Monaco without further intervention. The plan quality was weakly dependent on the parameter selection in the initial template and the choices of the step sizes for changing the constraint values.
conclusionAn automated planning platform to interface with Monaco was developed, and our reported tests showed preliminary results for prostate and head and neck cases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.