Evidence map›Paper›PMID 32179042›Full record

ArticleThe Annals of thoracic surgery2020

Sinus Hemodynamics After Transcatheter Aortic Valve in Transcatheter Aortic Valve.

Hoda Hatoum, Scott Lilly, Pablo Maureira, Juan Crestanello, Lakshmi Prasad Dasi

Open access · greenAbstract read
In one paragraph

Article in The Annals of thoracic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 10 citations in OpenAlex.

  1. Excessive Ostial Stent Protrusion: Evaluation of Management Strategies and Clinical Outcomes of the Side Flap Technique.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 2 countries.

Hoda HatoumDepartment of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia.
Scott LillyDivision of Cardiovascular Medicine, The Ohio State University, Columbus, Ohio.
Pablo MaureiraDepartment of Cardiovascular Surgery, Centre Hospitalier Universitaire de Nancy, Nancy, France.
Juan CrestanelloDepartment of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota.
Lakshmi Prasad DasiDepartment of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia. Electronic address: lakshmi.dasi@osumc.edu.
Georgia Institute of Technology · USCentre Hospitalier Régional et Universitaire de Nancy · FRMayo Clinic · USThe Ohio State University · US

Funding

Hyaluronan enhanced polymeric heart valve prosthesisR01HL119824 · NHLBI · OHIO STATE UNIVERSITY · PI DASI, LAKSHMI PRASAD · 2013 to 2017
$1.7M
American Heart Association-American Stroke Association 19POST34380804NHLBI NIH HHS R01 HL119824
6 · The paper itself

Abstract

backgroundThis study evaluated the effect of transcatheter aortic valve (TAV)-in-TAV on sinus hemodynamics and washout. With TAV becoming the standard procedure for aortic valve replacement and with the limited valve durability, a second intervention is necessary (TAV-in-TAV) after first TAV failure.

methodsSix arrangements of TAV-in-TAV were chosen for this study as follows: (1) Evolut 23 (Medtronic, Minneapolis, MN) in Evolut 26, (2) Evolut 23 in SAPIEN 3 23 (Edwards Lifesciences, Irvine, CA), (3) Evolut 26 in Evolut 26, (4) Evolut 26 in SAPIEN 23, (5) SAPIEN 3 23 in Evolut 26, and (6) SAPIEN 3 23 in SAPIEN 3 23. These TAV-in-TAV configurations were assessed in a pulse duplicator. Particle image velocimetry was performed.

resultsDuring systole, (1) the highest velocity was found with SAPIEN-in-SAPIEN (0.7 m/s) and the lowest was with Evolut 26-in-Evolut 26 (0.2 m/s); (2) the highest shear stress magnitude near the leaflet was with Evolut 23-in-SAPIEN (1.45 Pa) and the lowest was with Evolut 26-in-Evolut 26 (0.55 Pa); and (3) washout was almost equal in all sinuses of these cases (<2.5 cycles).

conclusionsThis study shows that TAV-in-TAV is highly dependent on the valve that is originally implanted and the valve to be implanted. Washout is not significantly degraded after TAV-in-TAV compared with valve-in-valve and TAV replacement. Further studies are needed to optimize valve size and selection.

Indexed as

Heart Valve ProsthesisAortic Valve StenosisHumansModels, CardiovascularProsthesis DesignShear StrengthSinus of ValsalvaStress, MechanicalTranscatheter Aortic Valve ReplacementVascular Resistance

Identifiers

PMID32179042
PMCPMC11069388
OpenAlexW3012050041

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.