Evidence map›Paper›PMID 32178311›Full record

ArticleSensors (Basel, Switzerland)2020

Method for Localization Aerial Target in AC Electric Field Based on Sensor Circular Array.

Wenbin Zhang, Peng Li, Nianrong Zhou, Chunguang Suo, Weiren Chen, Yanyun Wang, Jiawen Zhao, Yincheng Li

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wenbin ZhangFaculty of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, China.
Peng LiFaculty of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, China.
Nianrong ZhouSchool of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Chunguang SuoFaculty of Science, Kunming University of Science and Technology, Kunming 650504, China.
Weiren ChenFaculty of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, China.
Yanyun WangFaculty of Science, Kunming University of Science and Technology, Kunming 650504, China.
Jiawen ZhaoFaculty of Science, Kunming University of Science and Technology, Kunming 650504, China.
Yincheng LiFaculty of Science, Kunming University of Science and Technology, Kunming 650504, China.

Funding

Yunnan Power Grid Co., Ltd 2016KF00035
6 · The paper itself

Abstract

The traditional method of using electric field sensors to realize early warning of electric power safety distance cannot measure the distance of dangerous sources. Therefore, aiming at the electric field with a frequency of 50 to 60Hz (AC electric field), a new method for localization of aerial AC target by the capacitive one-dimensional spherical electric field sensor circular array is studied. This method can directly calculate the distance, elevation, and azimuth of the detector from the dangerous source. By combining the measurement principle of the spherical electric field sensor and the plane circular array theory, a mathematical model for the localization of aerial targets in an AC electric field is established. An error model was established using Gaussian noise and the effects of different layout parameters on the localization error were simulated. Based on mutual interference between sensors, minimum induced charge, and localization error, an optimal model for sensor layout was established, and it was solved by using genetic algorithms. The optimization results show that when the number of sensors is 4, the array radius is 20 cm, and the sensor radius is 1.5 cm, the ranging error is 8.4%. The detector was developed based on the layout parameters obtained from the optimization results, and the localization method was experimentally verified at 10 and 35 kV alarm distances. The experimental results show that when the detector is located at 10 kV alarm distance, the distance error is 0.18 m, the elevation error is 6.8°, and the azimuth error is 4.57°, and when it is located at 35 kV alarm distance, the distance error is 0.2 m, the elevation error is 4.8°, and the azimuth error is 5.14°, which meets the safety distance warning requirements of 10 and 35 kV voltage levels.

Indexed as

layout optimizationlocalization errorsafe distancesensor circular arraytarget settingvoltage level

Identifiers

PMID32178311
PMCPMC7146230

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.