Evidence map›Paper›PMID 32178307›Full record

ArticleSensors (Basel, Switzerland)2020

Continuous Vital Monitoring During Sleep and Light Activity Using Carbon-Black Elastomer Sensors.

Titus Jayarathna, Gaetano D Gargiulo, Paul P Breen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Artificial Intelligence-Driven Soft Bioelectronics for Self-Powered Respiration Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  2. Article
  3. A Flexible PVDF Sensor for Forcecardiography.Sensors (Basel, Switzerland) · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. [Research progress on wearable physiological parameter monitoring and its clinical applications].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2021
    Review
  9. Respiration Monitoring via Forcecardiography Sensors.Sensors (Basel, Switzerland) · 2021
    Article
  10. Review
  11. Review
  12. Study Protocol on the Validation of the Quality of Sleep Data from Xiaomi Domestic Wristbands.International journal of environmental research and public health · 2021
    Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Titus JayarathnaThe MARCS Institute, Western Sydney University, Milperra NSW 2560, Australia.ORCID 0000-0002-1849-4235
Gaetano D GargiuloSchool of Engineering, Western Sydney University, Penrith NSW 2751, Australia.ORCID 0000-0002-2616-2804
Paul P BreenThe MARCS Institute, Western Sydney University, Milperra NSW 2560, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The comfortable, continuous monitoring of vital parameters is still a challenge. The long-term measurement of respiration and cardiovascular signals is required to diagnose cardiovascular and respiratory diseases. Similarly, sleep quality assessment and the recovery period following acute treatments require long-term vital parameter datalogging. To address these requirements, we have developed "VitalCore", a wearable continuous vital parameter monitoring device in the form of a T-shirt targeting the uninterrupted monitoring of respiration, pulse, and actigraphy. VitalCore uses polymer-based stretchable resistive bands as the primary sensor to capture breathing and pulse patterns from chest expansion. The carbon black-impregnated polymer is implemented in a U-shaped configuration and attached to the T-shirt with "interfacing" material along with the accompanying electronics. In this paper, VitalCore is bench tested and compared to gold standard respiration and pulse measurements to verify its functionality and further to assess the quality of data captured during sleep and during light exercise (walking). We show that these polymer-based sensors could identify respiratory peaks with a sensitivity of 99.44%, precision of 96.23%, and false-negative rate of 0.557% during sleep. We also show that this T-shirt configuration allows the wearer to sleep in all sleeping positions with a negligible difference of data quality. The device was also able to capture breathing during gait with 88.9%-100% accuracy in respiratory peak detection.

Indexed as

ElastomersElectrocardiographyHeart RateHumansRespiratory RateSleepSootWalkingWearable Electronic DevicesElastomersSootconductive polymercontinuous respiratory monitoringhome sleep testsleep monitoringvital parameter monitoring

Identifiers

PMID32178307
PMCPMC7146453

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.