Evidence map›Paper›PMID 32175398›Full record

ArticleAnnals of translational medicine2020

Initial anticoagulation experience with standard-dose rivaroxaban after Watchman left atrial appendage occlusion.

Zhi-Chun Gu, Zhi-Qing Qiao, Zi-Yong Hao, Zheng Li, Li-Sheng Jiang, Heng Ge, Ben He, Jun Pu

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Outcomes in patients implanted with a Watchman device in relation to choice of anticoagulation and indication for implant.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022
    Article
  6. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Zhi-Chun GuDepartment of Pharmacy, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.
Zhi-Qing QiaoDepartment of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.
Zi-Yong HaoDepartment of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.
Zheng LiDepartment of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.
Li-Sheng JiangDepartment of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China.
Heng GeDepartment of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.
Ben HeDepartment of Cardiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China.
Jun PuDepartment of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.
Shanghai Jiao Tong University · CNRenji Hospital · CNShanghai Chest Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWarfarin is now recommended as the standard anti-thrombotic regimen to allow complete endothelialization over the Watchman device post percutaneous left atrial appendage occlusion (LAAO). However, the need for frequent monitoring, narrow therapeutic range, dietary restrictions and multiple drug interactions associated with warfarin have contributed to increasing uptake of non-vitamin K oral anticoagulants (NOACs) worldwide. At present, the feasibility and safety of NOACs instead of warfarin post-LAAO is lacking.

methodsPatients who underwent successful Watchman device implantation between October 1, 2016 and September 30, 2017 were enrolled in a retrospective database. And only patients who received rivaroxaban in the periprocedural period were included in this study. Transesophageal echocardiography (TEE) follow-up was scheduled at 6 weeks, at 6 months, and at 12 months post-implantation to detect device-related thrombosis (DRT) or peri-device leak. Meanwhile, thromboembolic and bleeding events were also evaluated at the time of follow-up.

resultsTotally, 57 Watchman devices were successfully implanted and 10 patients who were allocated to rivaroxaban at the dosage of 20 mg once daily were included. During the follow-up, none of the patients using rivaroxaban experienced DRT, peri-device leak, thromboembolic complications and major bleeding events, except for 2 patients who suffered minor bleeding during the 6 weeks follow-up.

conclusionsThis study suggests that a short course of standard-dose rivaroxaban following Watchman LAAO is associated with low incidence of thrombotic complications and bleeding events, and might be a feasible alternative regimen in Chinese. Further randomized trials and large sample of real-world studies are needed to validate our finding.

Indexed as

atrial fibrillation (AF)bleeding eventsdevice-related thrombosisLeft atrial appendage occlusion (LAAO)rivaroxaban

Identifiers

PMID32175398
PMCPMC7048987
OpenAlexW2999301559

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.