Evidence map›Paper›PMID 32170358›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2021

Surgeon-defined assessment is a poor predictor of knee balance in total knee arthroplasty: a prospective, multicenter study.

Samuel J MacDessi, Jil A Wood, Ashish D Diwan, Ian A Harris, SENSOR BALANCE Study Group

Abstract readMulticenter StudyRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. [Optimal lower limb alignment and soft tissue balancing strategy for robot-assisted total knee arthroplasty].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2021
    Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Samuel J MacDessiSydney Knee Specialists, Suite 201, Level 2, 131 Princes Hway, Kogarah, NSW, 2217, Australia. samuelmacdessi@sydneyknee.com.au.ORCID http://orcid.org/0000-0002-1578-7614
Jil A WoodSydney Knee Specialists, Suite 201, Level 2, 131 Princes Hway, Kogarah, NSW, 2217, Australia.
Ashish D DiwanSt George and Sutherland Clinical School, University of NSW, Kogarah, NSW, Australia.
Ian A HarrisWhitlam Orthopaedic Research Centre, Ingham Institute for Applied Medical Research, Liverpool, NSW, Australia.
SENSOR BALANCE Study Group

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe accuracy of surgeon-defined assessment (SDA) of soft tissue balance in total knee arthroplasty (TKA) is poorly understood despite balance being considered a significant determinant of surgical success. The study's hypothesis was that intra-operative SDA is a poor predictor of coronal balance in TKA.

methodsA prospective, multicenter study assessing accuracy of SDA of balance was conducted in 250 patients (285 TKAs). Eight surgeons and thirteen trainees participated, and all were blinded to sensor measurements. The primary outcome was test accuracy of SDA measured at 10°, 45° and 90° compared to sensor measures as the gold standard test. Cohen's kappa coefficient was calculated to determine chance-corrected agreement. Secondary outcomes include the relationship of SDA to level of surgical experience, analysis of between-surgeon differences, and the influence of patient and operative factors on SDA accuracy.

resultsAverage accuracy of SDA was 58.3%, 61.2% and 66.5% at 10°, 45° and 90° respectively. Cohen's kappa coefficient was 0.18 at all angles and rated as "slight agreement". SDA sensitivities to correctly identify a balanced knee (76.2% at 10°; 82.6% at 45°; 83.2% at 90°) were approximately twice specificities to correctly identify an unbalanced knee (42.6% at 10°; 34.1% at 45°; 41.4% at 90°). Surgical experience (surgeon versus trainee) had no effect on capacity to determine balance. Considerable between-surgeon variability was found (33-65% at 10°, 41-73% at 45°, 55-89% at 90°).

conclusionSDA was a poor predictor of balance, particularly when assessing the unbalanced TKA. Surgeon experience had no effect on test accuracy and considerable between-surgeon variability was recorded. These findings question the accuracy of SDA in TKA. TRIAL REGISTRATION NUMBER: ACTRN# 12618000817246.

Indexed as

AgedArthroplasty, Replacement, KneeBiomechanical PhenomenaFemaleHumansKnee JointKnee ProsthesisMaleMiddle AgedMonitoring, IntraoperativeOrthopedic SurgeonsOsteoarthritis, KneePostural BalanceProspective StudiesRange of Motion, ArticularSingle-Blind MethodAssessmentBalancePressureSensorsSoft tissueTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.