ArticleSensors (Basel, Switzerland)2020

Reusable, Non-Invasive, and Ultrafast Radio Frequency Biosensor Based on Optimized Integrated Passive Device Fabrication Process for Quantitative Detection of Glucose Levels.

Yang Li, Zhao Yao, Wenjing Yue, Chunwei Zhang, Song Gao, Cong Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yang LiSchool of Information Science and Engineering, University of Jinan, Jinan 250022, China.
Zhao YaoCollege of Microtechnology & Nanotechnology, Qingdao University, Qingdao 266071, China.ORCID 0000-0003-3030-4614
Wenjing YueSchool of Information Science and Engineering, University of Jinan, Jinan 250022, China.
Chunwei ZhangSchool of Information Science and Engineering, University of Jinan, Jinan 250022, China.
Song GaoSchool of Information Science and Engineering, University of Jinan, Jinan 250022, China.ORCID 0000-0001-9410-3040
Cong WangDepartment of Microwave Engineering, Harbin Institute of Technology, Harbin 150001, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The increase in the number of people suffering diabetes has been the driving force behind the development of glucose sensors to overcome the current testing shortcomings. In this work, a reusable, non-invasive and ultrafast radio frequency biosensor based on optimized integrated passive device fabrication process for quantitative detection of glucose level was developed. With the aid of the novel biosensor design with hammer-shaped capacitors for carrying out detection, both the resonance frequency and magnitude of reflection coefficient can be applied to map the different glucose levels. Meanwhile, the corresponding fabrication process was developed, providing an approach for achieving quantitative detection and a structure without metal-insulator-metal type capacitor that realizes low cost and high reliability. To enhance the sensitivity of biosensor, a 3-min dry etching treatment based on chlorine/argon-based plasma was implemented for realizing hydrophilicity of capacitor surface to ensure that the biosensor can be touched rapidly with glucose. Based on above implementation, a non-invasive biosensor having an ultrafast response time of superior to 0.85 s, ultralow LOD of 8.01 mg/dL and excellent reusability verified through five sets of measurements are realized. The proposed approaches are not limited the development of a stable and accurate platform for the detection of glucose levels but also presents a scheme toward the detection of glucose levels in human serum.

Indexed as

Biosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringDiabetes MellitusEquipment DesignHumansLimit of DetectionRadio WavesBlood Glucoseintegrated passive device fabrication processnon-invasive glucose biosensorquantitative detectionradio frequency resonatorreusable biosensorultrafast biosensor

Identifiers

PMID32168963
PMCPMC7146331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked