Evidence map›Paper›PMID 32166048›Full record

ArticleIEEE journal of translational engineering in health and medicine2019

Vision-Based Heart and Respiratory Rate Monitoring During Sleep - A Validation Study for the Population at Risk of Sleep Apnea.

Kaiyin Zhu, Michael Li, Sina Akbarian, Maziar Hafezi, Azadeh Yadollahi, Babak Taati

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Non-Contact Measurement of Cardiopulmonary Activity Using Software Defined Radios.IEEE journal of translational engineering in health and medicine · 2024
    Article
  11. A Novel Chest-Based PPG Measurement System.IEEE journal of translational engineering in health and medicine · 2024
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kaiyin Zhu1KITEToronto Rehabilitation Institute, University Health NetworkTorontoONM5G 2A2Canada.
Michael Li1KITEToronto Rehabilitation Institute, University Health NetworkTorontoONM5G 2A2Canada.
Sina Akbarian1KITEToronto Rehabilitation Institute, University Health NetworkTorontoONM5G 2A2Canada.
Maziar Hafezi1KITEToronto Rehabilitation Institute, University Health NetworkTorontoONM5G 2A2Canada.
Azadeh Yadollahi1KITEToronto Rehabilitation Institute, University Health NetworkTorontoONM5G 2A2Canada.
Babak Taati1KITEToronto Rehabilitation Institute, University Health NetworkTorontoONM5G 2A2Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A reliable, accessible, and non-intrusive method for tracking respiratory and heart rate is important for improving monitoring and detection of sleep apnea. In this study, an algorithm based on motion analysis of infrared video recordings was validated in 50 adults referred for clinical overnight polysomnography (PSG). The algorithm tracks the displacements of selected feature points on each sleeping participant and extracts respiratory rate using principal component analysis and heart rate using independent component analysis. For respiratory rate estimation (mean ± standard deviation), 89.89 % ± 10.95 % of the overnight estimation was accurate within 1 breath per minute compared to the PSG-derived respiratory rate from the respiratory inductive plethysmography signal, with an average root mean square error (RMSE) of 2.10 ± 1.64 breaths per minute. For heart rate estimation, 77.97 % ± 18.91 % of the overnight estimation was within 5 beats per minute of the heart rate derived from the pulse oximetry signal from PSG, with mean RMSE of 7.47 ± 4.79 beats per minute. No significant difference in estimation of RMSE of either signal was found according to differences in body position, sleep stage, or amount of the body covered by blankets. This vision-based method may prove suitable for overnight, non-contact monitoring of respiratory rate. However, at present, heart rate monitoring is less reliable and will require further work to improve accuracy.

Indexed as

Cardiopulmonary ratecomputer visionnoncontactsleep disordered breathing

Identifiers

PMID32166048
PMCPMC6889941

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.