Evidence map›Paper›PMID 32165963›Full record

ArticleOpen access Macedonian journal of medical sciences2019

Comparative Evaluation of Physical and Mechanical Properties of Different Brands of Primary Molar Stainless-Steel Crowns: An In Vitro Study.

Zhaleh Bamdadian, Nilgoon Pasdar, Abdolhamid Alhavaz, Shahram Ghasemi, Ali Bijani

Open access · diamondAbstract read
In one paragraph

Article in Open access Macedonian journal of medical sciences, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Observational
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Zhaleh BamdadianDepartment of Pediatric Dentistry, Faculty of Dentistry, Mazandaran University of Medical Sciences, Sari, Iran.
Nilgoon PasdarHealth Research Institute, Dental Material Research Center, Department of Pediatric Dentistry, Faculty of Dentistry, Babol University of Medical Sciences, Babol, Iran.
Abdolhamid AlhavazDental Material Research Center, Health Research Institute, Department of Prosthodontics, Babol University of Medical Sciences, Babol, Iran.
Shahram GhasemiFaculty of Chemistry, University of Mazandaran, Babolsar, Iran.
Ali BijaniSocial Determinant of Health Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran.
Babol University of Medical Sciences · IRMazandaran University of Medical Sciences · IRUniversity of Mazandaran · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThere is some cases of perforation and undesirable properties of some primary molars stainless steel crowns.

aimThe aim of this study was to compare the physical and mechanical properties of different commercial brands of these crowns.

methodsIn an in vitro study, 10 stainless steel tooth crowns of the second primary mandibular molars size 6 of 4 different commercial brands (a total of 280 crowns) were evaluated. These crowns were included KTR Pre-trimmed and Crimped Nichro Stainless Steel Primary Molar Crowns (KTR, China); 3M Stainless Steel Primary Molar Crowns (ESPE, St paul; USA); NuSmile SSC Pre-contoured (Inc, Houstone, TX; USA) and Kids crown (Shinghung, Seoul; Korea). Corrosion and galvanic corrosion, wear, microhardness, compressive strength, fatigue strength of crowns and weight percent of elements were investigated.

resultsThe highest rate of microhardness, compressive and Fatigue strength of the crowns were made by Nu Smile > 3M > Kids Crown > KTR respectively. The highest rate of corrosion potential in corrosion and Galvanic corrosion tests was in KTR > Kids crowns > 3M > Nu smile respectively. The order of crown wear was KTR > Kids Crown > 3M > Nu Smile respectively. The highest amount of nickel element was found in the Nu Smile crown and the highest amount of chrome in the 3M crown with a significant difference with others (p < 0.001). The KTR and Kids crowns lacked molybdenum.

conclusionThe results showed that Nu Smile crown has better physical and mechanical properties than other evaluated crowns in this study.

Indexed as

CorrosionCrownHardnessStainless steelWear

Identifiers

PMID32165963
PMCPMC7061362
OpenAlexW3006937814

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.