Evidence map›Paper›PMID 32164663›Full record

ArticleBMC musculoskeletal disorders2020

SCreg: a registration-based platform to compare unicondylar knee arthroplasty SPECT/CT scans.

Félix Dandois, Stijn De Buck, Lucas Beckers, Darshan Shah, Laura Slane, Hilde Vandenneucker, Lennart Scheys

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Félix DandoisDevelopment and Regeneration Department, Institute for Orthopaedic Research and Training, KU Leuven, 49 Herestraat - Box 805, 3000, Leuven, Belgium. felix.dandois@kuleuven.be.ORCID http://orcid.org/0000-0001-8852-5052
Stijn De BuckRadiology and Cardiology Department, University Hospitals Leuven, 49 Herestraat, 3000, Leuven, Belgium.
Lucas BeckersOrthopaedics Department, University Hospitals Leuven, 49 Herestraat, 3000, Leuven, Belgium.
Darshan ShahDevelopment and Regeneration Department, Institute for Orthopaedic Research and Training, KU Leuven, 49 Herestraat - Box 805, 3000, Leuven, Belgium.
Laura SlaneMechanical Engineering Department, University of Rochester, 500 Joseph C. Wilson Blvd, Rochester, NY, 14602, USA.
Hilde VandenneuckerDevelopment and Regeneration Department, Institute for Orthopaedic Research and Training, KU Leuven, 49 Herestraat - Box 805, 3000, Leuven, Belgium.
Lennart ScheysDevelopment and Regeneration Department, Institute for Orthopaedic Research and Training, KU Leuven, 49 Herestraat - Box 805, 3000, Leuven, Belgium.
Rega Institute for Medical Research · BEKU Leuven · BEUniversity of Rochester · US

Funding

Zimmer Biomet Not applicable
6 · The paper itself

Abstract

backgroundA combination of conventional computed tomography and single photon emitted computed tomography (SPECT/CT) provides simultaneous data on the intensity and location of osteoblastic activity. Currently, since SPECT/CT scans are not spatially aligned, scans following knee arthroplasty are compared by extracting average and maximal values of osteoblastic activity intensity from large subregions of the structure of interest, which leads to a loss of resolution, and hence, information. Therefore, this paper describes the SPECT/CT registration platform (SCreg) based on the principle of image registration to spatially align SPECT/CT scans following unicondylar knee arthroplasty (UKA) and allow full resolution intra-subject and inter-subject comparisons.

methodsSPECT-CT scans of 20 patients were acquired before and 1 year after UKA. Firstly, scans were pre-processed to account for differences in voxel sizes and divided in volumes of interest. This was followed by optimization of registration parameters according to their volumetric agreement, and alignment using a combination of rigid, affine and non-rigid registration. Finally, radiotracer uptakes were normalized, and differences between pre-operative and post-operative activity were computed for each voxel. Wilcoxon signed rank sum test was performed to compare Dice similarity coefficients pre- and post-registration.

resultsQualitative and quantitative validation of the platform assessing the correct alignment of SPECT/CT scans resulted in Dice similarity coefficient values over 80% and distances between predefined anatomical landmarks below the fixed threshold of (2;2;0) voxels. Locations of increased and decreased osteoblastic activity obtained during comparisons of osteoblastic activity before and after UKA were mainly consistent with literature.

conclusionsThus, a full resolution comparison performed on the platform could assist surgeons and engineers in optimizing surgical parameters in view of bone remodeling, thereby improving UKA survivorship.

Indexed as

AgedArthroplasty, Replacement, KneeFemaleHumansMaleMiddle AgedOsteoarthritis, KneePatient SatisfactionSingle Photon Emission Computed Tomography Computed TomographyTomography, X-Ray ComputedDice similarity coefficientOsteoblastic activityRegistrationSPECT/CTUKA

Identifiers

PMID32164663
PMCPMC7066757
OpenAlexW3011119879

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.