Evidence map›Paper›PMID 32164292›Full record

ArticleSensors (Basel, Switzerland)2020

A Camera Sensors-Based System to Study Drug Effects On In Vitro Motility: The Case of PC-3 Prostate Cancer Cells.

Maria Colomba Comes, Arianna Mencattini, Davide Di Giuseppe, Joanna Filippi, Michele D'Orazio, Paola Casti, Francesca Corsi, Lina Ghibelli, Corrado Di Natale, Eugenio Martinelli

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Maria Colomba ComesDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.
Arianna MencattiniDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.
Davide Di GiuseppeDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.ORCID 0000-0002-1731-8678
Joanna FilippiDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.
Michele D'OrazioDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.
Paola CastiDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.
Francesca CorsiDept. of Chemical Science and Technologies, University of Rome Tor Vergata, 00133 Roma, Italy.
Lina GhibelliDept. Biology, University of Rome Tor Vergata, 00133 Roma, Italy.
Corrado Di NataleDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.ORCID 0000-0002-0543-4348
Eugenio MartinelliDept. Electronic Engineering, University of Rome Tor Vergata, 00133 Roma, Italy.ORCID 0000-0002-6673-2066

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cell motility is the brilliant result of cell status and its interaction with close environments. Its detection is now possible, thanks to the synergy of high-resolution camera sensors, time-lapse microscopy devices, and dedicated software tools for video and data analysis. In this scenario, we formulated a novel paradigm in which we considered the individual cells as a sort of sensitive element of a sensor, which exploits the camera as a transducer returning the movement of the cell as an output signal. In this way, cell movement allows us to retrieve information about the chemical composition of the close environment. To optimally exploit this information, in this work, we introduce a new setting, in which a cell trajectory is divided into sub-tracks, each one characterized by a specific motion kind. Hence, we considered all the sub-tracks of the single-cell trajectory as the signals of a virtual array of cell motility-based sensors. The kinematics of each sub-track is quantified and used for a classification task. To investigate the potential of the proposed approach, we have compared the achieved performances with those obtained by using a single-trajectory paradigm with the scope to evaluate the chemotherapy treatment effects on prostate cancer cells. Novel pattern recognition algorithms have been applied to the descriptors extracted at a sub-track level by implementing features, as well as samples selection (a good teacher learning approach) for model construction. The experimental results have put in evidence that the performances are higher when a further cluster majority role has been considered, by emulating a sort of sensor fusion procedure. All of these results highlighted the high strength of the proposed approach, and straightforwardly prefigure its use in lab-on-chip or organ-on-chip applications, where the cell motility analysis can be massively applied using time-lapse microscopy images.

Indexed as

Drug Screening Assays, AntitumorAlgorithmsAntineoplastic AgentsBiomechanical PhenomenaCell MovementCluster AnalysisHumansImage Processing, Computer-AssistedMachine LearningMaleMicroscopyModels, StatisticalNormal DistributionPattern Recognition, AutomatedPC-3 CellsProstateAntineoplastic Agentscell-motilitydrug effect on in-vitroKeywords: camera sensorprostate cancer cells

Identifiers

PMID32164292
PMCPMC7085768

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.