Evidence map›Paper›PMID 32163378›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2020

Biomechanics of Anterior Ring Internal Fixation Combined with Sacroiliac Screw Fixation for Tile C3 Pelvic Fractures.

Lin Liu, Shicai Fan, Yuhui Chen, Yongxing Peng, Xiangyuan Wen, Donggui Zeng, Hui Song, Dadi Jin

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Lin LiuDepartment of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland).
Shicai FanDepartment of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland).
Yuhui ChenDepartment of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland).
Yongxing PengDepartment of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland).
Xiangyuan WenDepartment of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland).
Donggui ZengDepartment of Traumatic Orthopaedics, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, China (mainland).
Hui SongDepartment of Traumatic Orthopaedics, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, China (mainland).
Dadi JinDepartment of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland).
Third Affiliated Hospital of Southern Medical University · CNUniversity of Chinese Academy of Sciences · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Despite the development of minimally invasive techniques for pelvic fractures, performing minimally invasive surgery for Tile C3 pelvic fractures remains challenging. Thus, we propose use of anterior ring internal fixation combined with sacroiliac screw fixation for Tile C3 pelvic fractures. MATERIAL AND METHODS A normal pelvic finite element model (model 1) was established. Two-screw, three-screw, and four-screw anterior ring internal fixators and plate combined with sacroiliac screw Tile C3 pelvic fracture models (models 2, 3, 4, and 5, respectively) were also established. A vertical load of 600 N was applied on S1. The distribution of displacement and stress in the standing and sitting positions was compared. RESULTS Models 2, 3, 4, and 5 can provide effective fixation. Compared with model 1, in the erect position, the maximum displacement of models 2, 3, 4, and 5 increased by 66.51%, 65.36%, 35.16%, and 35.47% and the maximum stress increased by 201.78%, 130.65%, 100.82%, and 99.03%, respectively. Compared with model 1, in sitting position, the maximum displacement of models 2, 3, 4, and 5 increased by 9.1%, 11.04%, 5.57%, and 8.59% and the maximum stress increased by 157.73%, 118.02%, 98.32%, and 93.16%, respectively. CONCLUSIONS Anterior ring internal fixators combined with sacroiliac screws can effectively fix Tile C3 pelvic fractures.

Indexed as

Models, BiologicalAdultBiomechanical PhenomenaBone PlatesBone ScrewsFinite Element AnalysisFracture Fixation, InternalFractures, BoneHumansMalePelvic BonesSacroiliac Joint

Identifiers

PMID32163378
PMCPMC7092661
OpenAlexW3001131398

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.