Evidence map›Paper›PMID 32162045›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2021

Suture tape augmentation of the lateral ulnar collateral ligament increases load to failure in simulated posterolateral rotatory instability.

Alexander Ellwein, Luca Füßler, Manuel Ferle, Tomas Smith, Helmut Lill, Marc-Frederic Pastor

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.3field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Alexander EllweinDepartment of Orthopedic Surgery, Medical School Hannover, DIAKOVERE Annastift, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany. alexander.ellwein@diakovere.de.ORCID http://orcid.org/0000-0001-6055-4249
Luca FüßlerDepartment of Orthopedic Surgery, Medical School Hannover, DIAKOVERE Annastift, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany.
Manuel FerleLaboratory of Biomechanics and Biomaterials, Medical School Hannover, 30625, Hannover, Germany.
Tomas SmithDepartment of Orthopedic Surgery, Medical School Hannover, DIAKOVERE Annastift, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany.
Helmut LillDepartment of Orthopedic Surgery and Traumatology, DIAKOVERE Friederikenstift, Humboldtstr. 5, 30169, Hannover, Germany.
Marc-Frederic PastorDepartment of Orthopedic Surgery, Medical School Hannover, DIAKOVERE Annastift, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany.
Medizinische Hochschule Hannover · DE

Funding

AGA - Gesellschaft für Arthroskopie und Gelenkchirurgie 70
6 · The paper itself

Abstract

purposeSimple elbow dislocations are accompanied with lateral ulnar collateral ligament ruptures. For persisting instability, surgery is indicated to prevent chronic posterolateral rotatory instability. After lateral collateral ligament (LCL) complex repair the repair is protected by temporary immobilization, limited range of motion and hinged bracing. Internal bracing is an operative alternative augmenting the LCL repair using non-absorbable suture tapes. However, the stability of LCL repair with and without additional augmentation remains unclear. The hypothesis was that LCL repair with additional suture tape augmentation would improve load to failure. Secondary goal of this study was to evaluate different humeral fixation techniques. A humeral fixation using separate anchors for the LCL repair and the augmentation was not expected to provide superior stability compared to using only one single anchor.

methodsTwenty-one elbows were tested. A cyclic varus rotational torque of 0.5-3.5 Nm was applied in 90°, 60°, 30°, and 120° elbow flexion to the intact, torn, and repaired LCLs. The specimens were randomized into three groups: repair alone (group I), repair with additional internal bracing using two anchors (group II), repair using one humeral anchor (group III). A load-to-failure protocol was conducted.

resultsLoad to failure was significantly higher in groups II (26.6 Nm; P = 0.017) and III (23.18 Nm; P = 0.038) than in group I (12.13 Nm). No significant difference was observed between group II and III. All specimens lost reduction after LCL dissection by a mean of 4.48° ± 4.99° (range 0.66-15.82). The mean reduction gain after repair was 7.21° ± 4.97° (2.70-21.23; mean over reduction, 2.73°). The laxity was comparable between the intact and repaired LCLs (n.s.), except for varus movements at 30° in group II (P = 0.035) and 30° (P = 0.001) and 120° in group III (P = 0.008) with significantly less laxity. Inserting the ulnar suture anchor showed failure in the thread in 10 cases.

conclusionLCL repair with additional internal bracing yielded higher load to failure than repair alone. Repair with additional internal bracing for the humeral side using one anchor was sufficient. A higher primary stability would facilitate postoperative management and allow immediate functional treatment. Reducing the number of humeral anchors would save costs.

Indexed as

SuturesAgedBiomechanical PhenomenaCadaverCollateral Ligament, UlnarElbow InjuriesElbow JointFemaleHumansHumerusJoint InstabilityMaleMiddle AgedRange of Motion, ArticularRotationRuptureAugmentationCadaveric human elbowElbow dislocationLateral ulnar collateral ligamentLUCLPosterolateral rotatory instabilityReconstruction

Identifiers

PMID32162045
OpenAlexW3012097676

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.