Quantitative Screening of Cervical Cancers for Low-Resource Settings: Pilot Study of Smartphone-Based Endoscopic Visual Inspection After Acetic Acid Using Machine Learning Techniques.
Article in JMIR mHealth and uHealth, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.
- Accuracy of Smartphone Images of the Cervix After Acetic Acid Application for Diagnosing Cervical Intraepithelial Neoplasia Grade 2 or Greater in Women With Positive Cervical Screening: A Systematic Review and Meta-Analysis.JCO global oncology · 2021Pooled it
- Systematic review of artificial intelligence and digital-automated tools for screening, diagnosis and characterisation of primary ciliary dyskinesia.ERJ open research · 2026Article
- Integrating pocket colposcope and telecolposcopy into VIA-based screening at primary healthcare centers for cervical cancer prevention in LMICs.Frontiers in oncology · 2026Review
- Machine and Deep Learning for the Diagnosis, Prognosis, and Treatment of Cervical Cancer: A Scoping Review.Diagnostics (Basel, Switzerland) · 2025Review
- Deep dive into deep learning methods for cervical cancer detection and classification.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2025Review
- Automated analysis of digital medical images in cervical cancer screening: A systematic review.medRxiv : the preprint server for health sciences · 2024Article
- Current smartphone-assisted point-of-care cancer detection: Towards supporting personalized cancer monitoring.Trends in analytical chemistry : TRAC · 2024Article
- MFEM-CIN: A Lightweight Architecture Combining CNN and Transformer for the Classification of Pre-Cancerous Lesions of the Cervix.IEEE open journal of engineering in medicine and biology · 2024Article
- Optical imaging technologies forCurrent opinion in biomedical engineering · 2023Article
- A segmentation model to detect cevical lesions based on machine learning of colposcopic images.Heliyon · 2023Article
- A Review of Computer-Aided Diagnostic Algorithms for Cervical Neoplasia and an Assessment of Their Applicability to Female Genital Schistosomiasis.Mayo Clinic proceedings. Digital health · 2023Review
- Prevention Strategies and Early Diagnosis of Cervical Cancer: Current State and Prospects.Diagnostics (Basel, Switzerland) · 2023Review
- Cervical pre-cancerous lesion detection: development of smartphone-based VIA application using artificial intelligence.BMC research notes · 2022Article
- The Impact of Artificial Intelligence on Health Equity in Oncology: Scoping Review.Journal of medical Internet research · 2022Article
- Development of a multimodal mobile colposcope for real-time cervical cancer detection.Biomedical optics express · 2022Article
- Smartphone-Based Visual Inspection with Acetic Acid: An Innovative Tool to Improve Cervical Cancer Screening in Low-Resource Setting.Healthcare (Basel, Switzerland) · 2022Review
- Assessment of the implementation context in preparation for a clinical study of machine-learning algorithms to automate the classification of digital cervical images for cervical cancer screening in resource-constrained settings.Frontiers in health services · 2022Article
- Article
- Intelligent smartphone-based multimode imaging otoscope for the mobile diagnosis of otitis media.Biomedical optics express · 2021Article
- Smartphone-based imaging systems for medical applications: a critical review.Journal of biomedical optics · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundApproximately 90% of global cervical cancer (CC) is mostly found in low- and middle-income countries. In most cases, CC can be detected early through routine screening programs, including a cytology-based test. However, it is logistically difficult to offer this program in low-resource settings due to limited resources and infrastructure, and few trained experts. A visual inspection following the application of acetic acid (VIA) has been widely promoted and is routinely recommended as a viable form of CC screening in resource-constrained countries. Digital images of the cervix have been acquired during VIA procedure with better quality assurance and visualization, leading to higher diagnostic accuracy and reduction of the variability of detection rate. However, a colposcope is bulky, expensive, electricity-dependent, and needs routine maintenance, and to confirm the grade of abnormality through its images, a specialist must be present. Recently, smartphone-based imaging systems have made a significant impact on the practice of medicine by offering a cost-effective, rapid, and noninvasive method of evaluation. Furthermore, computer-aided analyses, including image processing-based methods and machine learning techniques, have also shown great potential for a high impact on medicinal evaluations.
objectiveIn this study, we demonstrate a new quantitative CC screening technique and implement a machine learning algorithm for smartphone-based endoscopic VIA. We also evaluated the diagnostic performance and practicability of the approach based on the results compared to the gold standard and from physicians' interpretation.
methodsA smartphone-based endoscope system was developed and applied to the VIA screening. A total of 20 patients were recruited for this study to evaluate the system. Overall, five were healthy, and 15 were patients who had shown a low to high grade of cervical intraepithelial neoplasia (CIN) from both colposcopy and cytology tests. Endoscopic VIA images were obtained before a loop electrosurgical excision procedure for patients with abnormal tissues, and their histology tissues were collected. Endoscopic VIA images were assessed by four expert physicians relative to the gold standard of histopathology. Also, VIA features were extracted from multiple steps of image processing techniques to find the differences between abnormal (CIN2+) and normal (≤CIN1). By using the extracted features, the performance of different machine learning classifiers, such as k-nearest neighbors (KNN), support vector machine, and decision tree (DT), were compared to find the best algorithm for VIA. After determining the best performing classifying model, it was used to evaluate the screening performance of VIA.
resultsAn average accuracy of 78%, with a Cohen kappa of 0.571, was observed for the evaluation of the system by four physicians. Through image processing, 240 sliced images were obtained from the cervicogram at each clock position, and five features of VIA were extracted. Among the three models, KNN showed the best performance for finding VIA within holdout 10-fold cross-validation, with an accuracy of 78.3%, area under the curve of 0.807, a specificity of 80.3%, and a sensitivity of 75.0%, respectively. The trained model performed using an unprovided data set resulted in an accuracy of 80.8%, specificity of 84.1%, and sensitivity of 71.9%. Predictions were visualized with intuitive color labels, indicating the normal/abnormal tissue using a circular clock-type segmentation. Calculating the overlapped abnormal tissues between the gold standard and predicted value, the KNN model overperformed the average assessments of physicians for finding VIA.
conclusionsWe explored the potential of the smartphone-based endoscopic VIA as an evaluation technique and used the cervicogram to evaluate normal/abnormal tissue using machine learning techniques. The results of this study demonstrate its potential as a screening tool in low-resource settings.