Evidence map›Paper›PMID 32159285›Full record

ArticleOrthopaedic surgery2020

Influence of Congruency Design on the Contact Stress of a Novel Hinged Knee Prosthesis Using Finite Element Analysis.

Jing-Yu Zhang, Dong-Mu Tian, Zhi-Peng Ren, Yong-Cheng Hu, Xiu-Chun Yu

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [The influence of articular surface conformity on the biomechanics of rotating hinge knee prostheses].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jing-Yu ZhangDepartment of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.ORCID https://orcid.org/0000-0003-4924-6418
Dong-Mu TianBeijing Weigao Yahua Artificial Joint Development Company, Beijing, China.
Zhi-Peng RenDepartment of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.
Yong-Cheng HuDepartment of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.ORCID https://orcid.org/0000-0002-9846-6735
Xiu-Chun YuDepartment of Orthopaedics, The 960th Hospital of the PLA Joint Logistice Support Force, Jinan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo investigate the contact stress and the contact area o tibial inserts and bushings with respect to different congruency designs in a spherical center axis and rotating bearing hinge knee prosthesis under gait cycle loading conditions using finite element analysis.

methodsNine prostheses with different congruency (different degrees of tibiofemoral conformity and different distances between the spherical center and the bushing) designs were developed with the same femoral and tibial components. The models were transferred to finite element software. The peak contact stresses and contact areas on tibial inserts and bushings under the gait cycle loading conditions were investigated and compared.

resultsFor tibial insert, the peak contact stress was the highest in the low conformity-long group (61.4486 MPa), and it was 1.88 times higher than that in the group with the lowest stress (moderate conformity-short group, 32.754 MPa). The contact area was the largest in the low conformity-long group (420.485 mm

conclusionThe results of our study showed that the congruency of the tibiofemoral surface and bushing surface should be considered carefully in the design of the spherical center axis and rotating bearing hinge knee prosthesis. Different levels of contact performance were observed with different congruency designs. In addition, the influence of contact stress and contact area on the polyethylene wear of rotating hinge knee prostheses should be confirmed with additional laboratory tests.

Indexed as

Finite Element AnalysisKnee ProsthesisMaterials TestingProsthesis DesignStress, MechanicalGaitHumansCongruencyContact areaContact stressFinite element analysisRotating hinge knee prosthesis

Identifiers

PMID32159285
PMCPMC7189048

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.