Evidence map›Paper›PMID 32157335›Full record

ReviewHNO2020

[Continuous intraoperative neuromonitoring (cIONM) in head and neck surgery-a review. German version].

P Stankovic, J Wittlinger, R Georgiew, N Dominas, S Hoch, T Wilhelm

Open access · hybridAbstract readReview
In one paragraph

Review in HNO, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Trends and Demographic Disparities in the Utilization of Intraoperative Neuromonitoring in the United States, 2008 to 2021.Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

P StankovicKlinik für HNO-Heilkunde, Kopf‑/Hals- und plastische Gesichtschirurgie, Sana Kliniken Leipziger Land, Rudolf-Virchow-Straße 2, 04552, Borna, Deutschland.ORCID https://orcid.org/0000-0002-0105-1489
J WittlingerUniversitätsklinik und Poliklinik für Hals-Nasen-Ohren-Heilkunde, Kopf- und Hals-Chirurgie, Martin-Luther-Universität Halle-Wittenberg, Halle/Saale, Deutschland.
R GeorgiewKlinik für HNO-Heilkunde, Kopf‑/Hals- und plastische Gesichtschirurgie, Sana Kliniken Leipziger Land, Rudolf-Virchow-Straße 2, 04552, Borna, Deutschland.
N DominasUniversitätsklinik für Hals‑, Nasen und Ohrenheilkunde, Phoniatrie und Pädaudiologie, Philipps-Universität Marburg, Marburg, Deutschland.
S HochUniversitätsklinik für Hals‑, Nasen und Ohrenheilkunde, Phoniatrie und Pädaudiologie, Philipps-Universität Marburg, Marburg, Deutschland.
T WilhelmKlinik für HNO-Heilkunde, Kopf‑/Hals- und plastische Gesichtschirurgie, Sana Kliniken Leipziger Land, Rudolf-Virchow-Straße 2, 04552, Borna, Deutschland. thomas.wilhelm@sana.de.ORCID https://orcid.org/0000-0003-1317-5224
Philipps University of Marburg · DESana Kliniken Leipziger Land · DEKlinik und Poliklinik für Hals-Nasen-Ohren-Heilkunde · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although the history of intraoperative neuromonitoring (IONM) dates back to the 19th century, the method did not evolve further than the mere differentiation of nerves until recently. Only the development of continuous IONM (cIONM) has allowed for non-stop analysis of excitation amplitude and latency during surgical procedures, which is nowadays integrated into the software of almost all commercially available neuromonitoring devices. The objective of cIONM is real-time monitoring of nerve status in order to recognize and prevent impending nerve injury and predict postoperative nerve function. Despite some drawbacks such as false-positive/negative alarms, technical artefacts, and rare adverse effects, cIONM remains a good instrument which is still under development. Active (acIONM) and passive (pcIONM) methods of cIONM are described in literature. The main fields of cIONM implementation are currently thyroid surgery (in which the vagal nerve is continuously stimulated) and surgery to the cerebellopontine angle (in which the facial nerve is either continuously stimulated or the discharge signal of the nerve is analyzed via pcIONM). In the latter surgery, continuous monitoring of the cochlear nerve is also established.

Indexed as

Intraoperative ComplicationsMonitoring, IntraoperativeCerebellopontine AngleFacial NerveHumansThyroidectomyVocal Cord ParalysisCerebellopontine angleFacial nerveIntraoperative neurophysiological monitoringThyroidectomyVagal nerve

Identifiers

PMID32157335
PMCPMC7591407
OpenAlexW3011138559

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.