Evidence map›Paper›PMID 32154080›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2020

Atomic Scale Origin of Metal Ion Release from Hip Implant Taper Junctions.

Shanoob Balachandran, Zita Zachariah, Alfons Fischer, David Mayweg, Markus A Wimmer, Dierk Raabe, Michael Herbig

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
6.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Atomic Scale Origin of Metal Ion Release from Hip Implant Taper Junctions.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Shanoob BalachandranDepartment Microstructure Physics and Alloy Design Max-Planck-Institut für Eisenforschung GmbH Max-Planck-Straße 1 Düsseldorf 40237 Germany.ORCID https://orcid.org/0000-0002-1065-1216
Zita ZachariahDepartment Microstructure Physics and Alloy Design Max-Planck-Institut für Eisenforschung GmbH Max-Planck-Straße 1 Düsseldorf 40237 Germany.
Alfons FischerDepartment Microstructure Physics and Alloy Design Max-Planck-Institut für Eisenforschung GmbH Max-Planck-Straße 1 Düsseldorf 40237 Germany.
David MaywegDepartment Microstructure Physics and Alloy Design Max-Planck-Institut für Eisenforschung GmbH Max-Planck-Straße 1 Düsseldorf 40237 Germany.
Markus A WimmerDepartment of Orthopedic Surgery Rush University Medical Center 1611 W. Harrison St. Chicago IL 60612 USA.
Dierk RaabeDepartment Microstructure Physics and Alloy Design Max-Planck-Institut für Eisenforschung GmbH Max-Planck-Straße 1 Düsseldorf 40237 Germany.
Michael HerbigDepartment Microstructure Physics and Alloy Design Max-Planck-Institut für Eisenforschung GmbH Max-Planck-Straße 1 Düsseldorf 40237 Germany.
Max-Planck-Institut für Nachhaltige Materialien · DERush University Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Millions worldwide suffer from arthritis of the hips, and total hip replacement is a clinically successful treatment for end-stage arthritis patients. Typical hip implants incorporate a cobalt alloy (Co-Cr-Mo) femoral head fixed on a titanium alloy (Ti-6Al-4V) femoral stem via a Morse taper junction. However, fretting and corrosion at this junction can cause release of wear particles and metal ions from the metallic implant, leading to local and systemic toxicity in patients. This study is a multiscale structural-chemical investigation, ranging from the micrometer down to the atomic scale, of the underlying mechanisms leading to metal ion release from such taper junctions. Correlative transmission electron microscopy and atom probe tomography reveals microstructural and compositional alterations in the subsurface of the titanium alloy subjected to in vitro gross-slip fretting against the cobalt alloy. Even though the cobalt alloy is comparatively more wear-resistant, changes in the titanium alloy promote tribocorrosion and subsequent degradation of the cobalt alloy. These observations regarding the concurrent occurrence of electrochemical and tribological phenomena are vital to further improve the design and performance of taper junctions in similar environments.

Indexed as

biomedical titanium alloyscobalt–chromium–molybdenum alloysMorse taper junctionstotal hip replacementtribocorrosion

Identifiers

PMID32154080
PMCPMC7055581
OpenAlexW3001535526

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked